MIB Viewer

genEquipSynchronizationNodeMode

OBJECT-TYPE
1.3.6.1.4.1.2281.10.8.3.10
Access
read-write
Status
mandatory
Sub-identifiers
0
This parameter allows forcing a certain source as the active source for the system reference clock. When forced, the active source is specified by genEquipSynchronizationForceSource. In automatic mode, the active source is determined by quality and priority of the relevant interfaces (as configured in table genEquipSynchronizationSrcTable).
INTEGER { automatic (0), force (1) }