iso/org/dod/internet/private/enterprises/.2011/huaweiMgmt/hwEthernetPort/.6/hw10GEOpticsModuleInformationTable/hw10GEOpticsModuleInformationEntry/hw10GEOpticsMDAuxInputTwo
hw10GEOpticsMDAuxInputTwo
OBJECT-TYPE
1.3.6.1.4.1.2011.5.14.6.3.1.78
Description
Indicate which quantity is monitored by each auxiliary A/D channel two. Options: 1. auxInputType1(0) -Auxiliary monitoring not implemented 2. auxInputType2(1) -APD Bias Voltage 3. auxInputType4(3) -TEC Current (mA) 4. auxInputType5(4) -Laser Temperature 5. auxInputType6(5) -Laser Wavelength 6. auxInputType7(6) -+5V Supply Voltage 7. auxInputType8(7) -+3.3V Supply Voltage 8. auxInputType9(8) -+1.8V Supply Voltage 9. auxInputType10(9) 10. auxInputType11(10) -+5V Supply Current 11. auxInputType14(13) -+3.3V Supply Current 12. auxInputType15(14) -+1.8V Supply Current 13. auxInputType16(15) 14. invalid(-1) -invalid value
Syntax
INTEGER { auxInputType1(0), auxInputType2(1), auxInputType4(3), auxInputType5(4), auxInputType6(5), auxInputType7(6), auxInputType8(7), auxInputType9(8), auxInputType10(9), auxInputType11(10), auxInputType14(13), auxInputType15(14), auxInputType16(15), invalid(-1) }