MIB Viewer

hwAutoSwitchOverStatus

OBJECT-TYPE
1.3.6.1.4.1.2011.6.22.3.5
Access
read-write
Status
current
Sub-identifiers
0
Status of auto switchover function. If the value of switchover switch hwSwitchOverStatus is off(2), the system cannot perform the active/standby switchover. Options: 1.on(1) -indicates that the automatic switchover is enabled. In this case, if the values of the hwSwitchOverPeriod, hwSwitchOverInverseDayNo, and hwSwitchOverTime are set, the system performs the automatic switchover periodically; if the values of the hwSwitchOverPeriod, hwSwitchOverInverseDayNo, and hwSwitchOverTime are not set or only partially set, the objects that are not set with values use the default value, and the system also performs the automatic switchover periodically. 2.off(2) -indicates that the automatic switchover is disabled. If this object is not set with a value, the system does not perform the automatic switchover. Default { off }
INTEGER { on(1), off(2) }