MIB Viewer

hwE1PTPErrAlarmSet

OBJECT-TYPE
1.3.6.1.4.1.2011.6.113.1.6.1.7
Access
read-write
Status
current
Sub-identifiers
0
Indicates set e1 error alarm switch,from left to right,each bit respresent a switch,default:111000 Options: 1.bit0(0) -indicates report pcm line fault alarm 2.bit1(1) -indicates when error rate reached ULF(Unconditional Line Fai2008-5-30 14:24lure)threshold,report pcm line fault alarm 3.bit2(2) -indicates when error rate reached OLF(Optional Line Failure) threshold,report pcm line fault alarm 4.bit3(3) -indicates when error rate reached LDT(Line Disturbance Transient Event) threshold,report E1 digital line transient event alarm 5.bit4(4) -indicates when E1 frame slip frequency exceeded in observation interval reached degraded threshold,report event alarm 6.bit5(5) -indicates when any line temporary event occurs,report event alarm
BITS{bit0(0),bit1(1),bit2(2),bit3(3),bit4(4),bit5(5)}