MIB Viewer

hwPstnPTPAdminOper

OBJECT-TYPE
1.3.6.1.4.1.2011.6.113.1.2.1.5
Access
read-write
Status
current
Sub-identifiers
0
Indicates the maintenance operation of the physical layer of the PSTN port. Options: 1.reset(1) -indicates the maintenance operation is reset 2.localLoop(2) -indicates the maintenance operation is local loop 3.remoteLoop(3) -indicates the maintenance operation is remote loop 4.cancelLoop(4) -indicates the maintenance operation is cancel loop 5.clearLineFault(5) -indicates the maintenance operation is clear line fault 6.invalidvalue(-1) -indicates an invalid value.
INTEGER{reset(1),localLoop(2),remoteLoop(3),cancelLoop(4),clearLineFault(5),invalidvalue(-1)}