MIB Viewer

hwSwitchOverStatus

OBJECT-TYPE
1.3.6.1.4.1.2011.6.22.3.1
Access
read-write
Status
current
Sub-identifiers
0
The switch of the active/standby switchover. Options: 1. on(1) -indicates that the active/standby switchover is enabled. 2. off(2) -indicates that the active/standby switchover is disabled. If the active/standby switchover is disabled, the system cannot perform data synchronization between the active and standby control boards, manual active/standby switchover, and automatic active/standby switchover. Default:on(1)
INTEGER { on(1), off(2) }