MIB Viewer

hwVOPINPDelayConfProfMinProtectionUs

OBJECT-TYPE
1.3.6.1.4.1.2011.6.144.1.1.16.1.7
Access
read-create
Status
current
Sub-identifiers
0
If retransmission is not used in upstream direction, this parameter specifies the minimum impulse noise protection for the upstream bearer channel if it is transported over DMT symbols with a subcarrier spacing of 4.3125 kHz. The impulse noise protection is expressed in DMT symbols with a subcarrier spacing of 4.3125 kHz and can take the values 1/2 and any integer from 0 to 16, inclusive. If the xTU does not support the configured INPMIN value, it shall use the nearest supported impulse noise protection greater than INPMIN. Unit: symbols.
Xdsl2SymbolProtection