MIB Viewer

hwxdslDynamicProfDpboFMin

OBJECT-TYPE
1.3.6.1.2.1.10.94.1.1.65550.1.28
Access
read-create
Status
current
Sub-identifiers
0
DPBOFMIN defines the minimum frequency from which the DPBO shall be applied. It shall be coded as a 16 bits unsigned integer representing a frequency in multiple of 4.3125 KHz. The range of valid values is from 0 kHz (coded as 0) to 8832 kHz (coded as 2048). The invalid value is 65535. If data is invalid, the invalid value will be returned. Range: 0-2048 Unit: 4.3125 KHz
Unsigned32 (0..2048)