MIB Viewer

igOperationalStatus

OBJECT-TYPE
1.3.6.1.4.1.5504.4.3.1.1.1.10
Access
read-only
Status
current
Sub-identifiers
0
GR-303-CORE R5-22 [274] Upon request by a remote managing system (eg, ZMS), an RDT shall provide a managing system with the RDT operational status indicating whether it is fully inoperable and unable to provide service to the user, or it is fully operable and available for use. Valid values are operable, inoperable, standby, inoperableIsInProgress and inoperableOosInProgress. Clarification table of igAdminStatus and igOperationalStatus: igAdminStatus igOperationalStatus Description outOfService operable not valid outOfService inoperable admin of service outOfService standby not valid inService operable normal operations inService inOperable fault inService standby normal operations
INTEGER { operable(1), inoperable(2), standby(3), inoperableIsInProgress(4), inoperableOosInProgress(5) }