MIB Viewer

juniFrDlcmiDceErrorThreshold

OBJECT-TYPE
1.3.6.1.4.1.4874.2.2.10.1.1.2.1.16
Access
read-create
Status
current
Sub-identifiers
0
The minimum number of errors that must be observed within the number of events specified by juniFrDlcmiDceMonitoredEvents, to declare the interface down. 'error' is lack of receipt of a Status Enquiry within the interval specified by juniFrDlcmiDcePollingInterval (T392). Pertains to DCE/NNI operation only. This parameter can be reconfigured only when the Frame Relay interface is acting as a DCE or NNI.
Integer32 (1..10)