MIB Viewer

juniHdlcIfRowStatus

OBJECT-TYPE
1.3.6.1.4.1.4874.2.2.9.1.2.1.2
Access
read-create
Status
current
Sub-identifiers
0
Controls creation/deletion of entries in this table according to the RowStatus textual convention, constrained to support the following values only: createAndGo destroy To create an entry in this table, the following entry objects MUST be explicitly configured: juniHdlcIfRowStatus juniHdlcIfLowerIfIndex In addition, when creating an entry the following conditions must hold: A value for juniHdlcIfIndex must have been determined previously, by reading juniHdlcNextIfIndex. The interface identified by juniHdlcIfLowerIfIndex must exist. A corresponding entry in ifTable/ifXTable/juniIfTable is created/ destroyed as a result of creating/destroying an entry in this table.
RowStatus