MIB Viewer

lCV24HrThreshold

OBJECT-TYPE
1.3.6.1.4.1.351.110.4.3.1.2.1.1.12
Access
read-write
Status
current
Sub-identifiers
0
Code Violation - is the occurence of a received CRC-6 code that is not identical to the corresponding locally. The value set in this object determines the value which when exceeded in a sliding 24 hour window causes a statistical alarm to be declared. The threshold is checked every 15 minutes for the preceding 24 hour interval
Integer32 (0..2147483647)