MIB Viewer

mcmescConnTxOcmShelfSlot

OBJECT-TYPE
1.3.6.1.4.1.4253.1.18.6.1.45
Access
read-write
Status
mandatory
Source
LUXN-MIB
Sub-identifiers
0
Add a connection from MCMESC Link-Tx to an OCM CPE-Rx by specifying the OCM's shelf and slot. The format is shlef,slot. If either MCMESC Link-Tx or specified OCM CPE-Rx has already had connection, an error will be returned. If the card specified by shelf,slot is not ocm type, an error will be returned. A get on this variable will always return 0,0.
DisplayString (SIZE (0..10))