MIB Viewer

mcmescSetState

OBJECT-TYPE
1.3.6.1.4.1.4253.1.18.6.1.52
Access
read-write
Status
mandatory
Source
LUXN-MIB
Sub-identifiers
0
Instruct the mcmesc card to do either a reset or loopback. A get on this will always return an other. If the card is in self-test, an error will be returned. If the card is already in any loopback, and try to turn on another loopback, an error will be returned.
INTEGER { other(1), resetWithCurrentConfiguration(2), nearEndCardLoopback(3), networkCardLoopback(4), nearEndPort1Loopback(5), nearEndPort2Loopback(6), nearEndPort3Loopback(7), nearEndPort4Loopback(8), nearEndPort5Loopback(9), nearEndPort6Loopback(10), nearEndPort7Loopback(11), nearEndPort8Loopback(12), nearEndPort9Loopback(13), nearEndPort10Loopback(14), nearEndPort11Loopback(15), nearEndPort12Loopback(16), networkPort1Loopback(17), networkPort2Loopback(18), networkPort3Loopback(19), networkPort4Loopback(20), networkPort5Loopback(21), networkPort6Loopback(22), networkPort7Loopback(23), networkPort8Loopback(24), networkPort9Loopback(25), networkPort10Loopback(26), networkPort11Loopback(27), networkPort12Loopback(28), disableLoopback(29) }