MIB Viewer

mspCommand

OBJECT-TYPE
1.3.6.1.4.1.1038.130.10.2.1.11
Access
read-write
Status
current
Sub-identifiers
0
Manual or forced commands can be apply to the protection switch. The forced and manual switch can be refused or cleared by equipment if a higher priority APS command is received or if the protection chanel is down. When this field is set to manual or forced, the mspTraffic field becomes read-write, and a set can be issued to specifie on which chanel the command does apply. Commands: LP (Lockout of Protection) LW (Lockout of Working channel) FSW (Forced Switch of a Working channel to protection) FSP (Forced Switch of a Protection channel to working) case 1+1 MSW (Manual Switch of a Working channel to protection) MSp (Manual Switch of a Protection channel to working) case 1+1 EXER (EXERcise)
MspCommand