MIB Viewer

ntcAsiInPrbsGenPidHandling

OBJECT-TYPE
1.3.6.1.4.1.5835.5.2.800.1.7.3
Access
read-write
Status
current
Sub-identifiers
0
Configuration of the PID (Packet Identifier) handling in the PRBS Generator. Configuration of the test generator to generate transport stream packets with a valid transport stream header. The configured PID is inserted in the transport stream header and the continuity counter is incrementing. Possible settings; - Off: Transport stream packets are generated without a valid transport stream header. In this case, a 0x47 sync marker is generated followed by 187 test bytes. - On: When enabled, transport stream packets are generated with a configurable PID. (A burst of TS packets will be generated with a configurable of number data packets and a configurable number of null packets.)
NtcEnable