oaLdOAmplifierCardAlarmStatus

OBJECT-TYPE
1.3.6.1.4.1.6926.1.41.12.2.1.20
Access
read-only
Status
mandatory
Sub-identifiers
0
The Optical Amplifier Alarms. This object is organised as a bit map. Each bit represents an alarm. If the object is zero - no alarm is active. 0x0000 ('0000 0000 0000 0000'B) - Normal (No alarm) 0x0001 ('0000 0000 0000 0001'B) - Optical Input alarm 0x0002 ('0000 0000 0000 0010'B) - Optical Output alarm 0x0004 ('0000 0000 0000 0100'B) - Optical Input 2 (Back Reflection alarm for module EM800-OAR12) 0x0008 ('0000 0000 0000 1000'B) - Module Temperature alarm 0x0010 ('0000 0000 0001 0000'B) - Pump Temperature 0x0020 ('0000 0000 0010 0000'B) - Pump Drive Current alarm 0x0040 ('0000 0000 0100 0000'B) - Power Supply Voltage alarm 0x0080 ('0000 0000 1000 0000'B) - Auto-shutdown 0x0100 ('0000 0001 0000 0000'B) - Reflected Power High alarm Any combination of the bits represent the combination of the alarms
OCTET STRING (SIZE(2))