MIB Viewer

olsrv2PHoldTime

OBJECT-TYPE
1.3.6.1.2.1.219.1.1.11
Access
read-write
Status
current
Sub-identifiers
0
olsrv2PHoldTime corresponds to P_HOLD_TIME of OLSRv2 and represents the period after receipt of a message that is processed by this router for which that information is recorded, in order that the message is not processed again if received again. Guidance for setting this object may be found in Section 5 of the OLSRv2 specification (RFC 7181), which indicates that: o olsrv2PHoldTime > 0 o This parameter SHOULD be greater than the maximum difference in time that a message may take to traverse the MANET, taking into account any message forwarding jitter as well as propagation, queuing, and processing delays. This object is persistent, and when written, the entity SHOULD save the change to non-volatile storage.
Unsigned32