MIB Viewer

olsrv2TcMinInterval

OBJECT-TYPE
1.3.6.1.2.1.219.1.1.7
Access
read-write
Status
current
Sub-identifiers
0
olsrv2TcMinInterval corresponds to TC_MIN_INTERVAL of OLSRv2 and represents the minimum interval between transmission of two successive TC messages by this router. Guidance for setting this object may be found in Section 5 of the OLSRv2 specification (RFC 7181), which indicates that: o olsrv2TcInterval >= olsrv2TcMinInterval The OLSRv2 protocol may choose to represent this time interval in terms of the 8-bit exponent-mantissa form defined in Section 5 of RFC 5497. When this is the case, this object value MUST be translated from the integer form represented in this MIB module into the exponent-mantissa form for the OLSRv2 protocol to use according to the algorithm defined in Section 5 of RFC 5497 for finding the next larger time value within the exponent-mantissa format. This object is persistent, and when written, the entity SHOULD save the change to non-volatile storage.
Olsrv2TimeValueCompressedForm32TC