MIB Viewer

optApsConfigRevertive

OBJECT-TYPE
1.3.6.1.4.1.4515.1.11.1.1.1.12
Access
read-create
Status
current
Sub-identifiers
0
This object is used to configure the APS revertive or nonrevertive option (read-write). revertive : Will switch the working connection back to active state after the Wait-To-restore interval has expired and the working connection Signal-Fault/Signal-Degrade has been cleared. Please refer to 'optApsWaitToRestore' for description of Wait-To-Restore interval. nonrevertive : The protection connection continues to be the active connection, The active connection does not switch to the working connection.
INTEGER { nonrevertive(1), revertive(2) }