MIB Viewer

pm1001lhrMesrxfp1LiRxPowerMeasPortn

OBJECT-TYPE
1.3.6.1.4.1.20044.22.3.3.212.1.2
Access
read-only
Status
current
Sub-identifiers
0
Line Optical Module Rx Power :This OID gives the receive power value of the XFP or OTX plugged in line #n, read from the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV)-40) (Unit = dBm) <Help> This measure gives the Rx optical power of the line transceiver
INTEGER (0..65535)