MIB Viewer

ppCfgMtaBatteryReplaceReporting

OBJECT-TYPE
1.3.6.1.4.1.4115.10.1.25
Access
read-write
Status
current
Sub-identifiers
0
Determines how the REPLACE BATTERY condition for a TM02DG102 Hardware rev. 6 is reported. Choices are: - Same criteria as for all other battery units (value == 1) - Reports only after a degraded battery condition persists for at least 72 hours. (value == 2)
INTEGER { immediate(1), delayed(2) }