MIB Viewer

radioAtpcManual

OBJECT-TYPE
1.3.6.1.4.1.2544.1.11.7.3.5.1.1.5.9.1.7
Access
read-create
Status
current
Sub-identifiers
0
Enables/disables Atpc Manual operation. When the feature is enabled there are 2 behaviour: - (enable) after an air los the ODU transmits the maximum available power - (enable-min-power) after an air los the ODU transmits the minimum available power.
INTEGER { disable (1), enable (2), enable-min-power (3) }