MIB Viewer

reachDSLSpectrumMgmtLoopMeasurementMethod

OBJECT-TYPE
1.3.6.1.4.1.1795.2.24.2.6.20.1.6
Access
read-only
Status
current
Sub-identifiers
0
This object has been deprecated. The corresponding object in the new pdn_spectrumMgmt.mib should be used instead. This object indicates the measurement method used in describing the Loop Length of a circuit. Following are the details of each of the options: none(1) - Indicates that the Spectral Compliance is NOT dependant on any Loop Length measurements or configurations. loopLength(2) - The 'ConfLoopLength' object is used to determine spectral compliance. The 'ConfEWL' & 'ConfQuadMode' objects are not used in this mode. ewl(3) - The 'ConfEWL' object is used to configure the estimated loop length, which is used to determine spectral compliance. In this mode the 'ConfLoopLength' & 'ConfQuadMode' objects are not used. quadMode(4) - The 'ConfQuadMode' object is used to determine spectral compliance. The 'ConfEWL' & 'ConfLoopLength' objects are not used in this mode. This object determines which of the three objects : 'ConfEWL', 'ConfLoopLength' or 'ConfQuadMode' is used (if any) to enforce spectrally compliant maximum 'Tx Rates' and the maximum allowed 'Tx Power' on a given circuit.
INTEGER { none(1), loopLength(2), ewl(3), quadMode(4) }