MIB Viewer

referenceSec

OBJECT-TYPE
1.3.6.1.4.1.193.223.2.7.1.1.33
Access
read-write
Status
current
Sub-identifiers
0
Each modulation is compliant to a Reference Spectrum Efficiency Class (RSEC). When running Adaptive Coding/Modulation, one SEC has to be selected for all the coding/modulations between selectedMinACM and selectedMaxACM. This parameter is called Reference SEC. This setting will affect availableMaxOutputPower, in order to fulfill spectrum requirements. Wanted frameId, txFrequency, rxFrequency, referenceSec, selectedMinAcm and selectedMaxAcm must be a valid combination.
INTEGER { noAvailable(1), sec2(2), sec4L(4), sec4H(5), sec5B(7), sec6B(9), sec5LB(10), sec5HB(11), sec6LB(12), sec6HB(13), sec7B(14), unknown(15) }