MIB Viewer

s3EnetRedPortSwitchoverStatus

OBJECT-TYPE
1.3.6.1.4.1.45.1.3.2.3.3.1.8
Access
read-write
Status
mandatory
Sub-identifiers
0
The switchover status of the redundant port pair. The following values can be written: timedSwitchover(2)...Immediately causes the active port to become the standby port, and the standby port to become the active port. Then once the value of s3EnetRedPortSwitchoverTime has elapsed to zero, the ports revert back to their orignal roles. The following values can be read: other(1).............The port is NOT undergoing a timed switchover. timedSwitchover(2)...The port is undergoing a timed switchover. Notes: 1.) When writing timedSwitchover(2) to this object, the SET request must also specify a value for the object s3EnetRedSwitchoverTime. 2.) Once the timed switchover has taken place, the value of this object reverts from timedSwitchover(2) to other(1).
INTEGER { other(1), timedSwitchover(2) }