MIB Viewer

sleMplsTpOamMaintanceEntityControlMpType

OBJECT-TYPE
1.3.6.1.4.1.6296.101.16.17.2.2.9
Access
read-write
Status
current
Sub-identifiers
0
Indicates the maintenance point type within the MEG. The object should have the value mep (1), only in the Ingress or Egress nodes of the transport path. The object can have the value mip (2), in the intermediate nodes and possibly in the end nodes of the transport path.