MIB Viewer

smCfgCtrlOnResetEnableDisable

OBJECT-TYPE
1.3.6.1.4.1.2.3.51.2.22.3.1.1.1.9
Access
read-write
Status
mandatory
Source
BLADE-MIB
Sub-identifiers
0
Switch module configuration control on resets (default and unsolicited). When set to enabled, the factory default IP configuration will become active when the I/O module is reset to factory defaults by either the management module or the I/O module. If an I/O module reset is initiated by a source other than the management module then the previous IP configuration will be in affect. In both these cases the MM will lose IP communications with the IOM. This MIB object can not be set, if AMM grants switch module the Protected Mode permission and switch module goes into Protected Mode. NOTE: The numeric values for the enumerations for enabled and disabled are non-traditional (i.e. - 0 and 1 are swapped), however, they cannot be changed since this MIB is already published. NOTE: This MIB object is not applicable to modules that are running in Network Address Translation (NAT) Mode. A value of disabled(1) will be returned.
INTEGER { enabled(0), disabled(1) }