swPimRegisterProbeTime

OBJECT-TYPE
1.3.6.1.4.1.171.12.52.2.1
Access
read-write
Status
current
Sub-identifiers
0
Used to set a time to send a probe message from the Designated Router (DR) to the Rendezvous Point (RP) before the Register Suppression time expires. If a Register Stop message is received by the DR, the Register Suppression Time will be restarted. If no Register Stop message is received within the probe time, Register Packets will be resent to the RP. The default value is 5 seconds.
Integer32 (1..127)