MIB Viewer

sysCBuRecMode

OBJECT-TYPE
1.3.6.1.4.1.164.3.3.1.6.2.1.10
Access
read-write
Status
current
Sub-identifiers
0
Recovery Mode. This object determines if after recovery of the Primary Link (used in Vmux) it will become on-line again or not: auto - automatic. In this case, the failed Link will become on-line again after recovery, automatically. manual - In this case, the failed Link will not become on-line again after recovery but user can manually flip to this Link.
INTEGER { auto (2), manual (3) }