MIB Viewer

sysSSelfTestResult

OBJECT-TYPE
1.3.6.1.4.1.164.3.3.1.3.15
Access
read-only
Status
current
Sub-identifiers
0
The test is performed by the active Common Logic card. The result will be a sum of 2**n according to the following bit convention: For DXC: bit 0 Database 1 Checksum Error (LSB) bit 1 Database 2 Checksum Error bit 2 I/O Expander Error bit 3 Counter Error bit 4 Matrix DPR Error bit 5 PS-A 5 Volt Error bit 6 PS-A 12 Volt Error bit 7 PS-B 5 Volt Error bit 8 PS-B 12 Volt Error bit 9 EPROM Failure For FCD: bit 0 I/O Expander Error (LSB) bit 1 Counter Error bit 2 EPROM Failure bit 3 Illegal Sys Config bit 4 SFIFO bit 5 EPIC Failure (ISDN) bit 6 XL Flash Fail bit 7 XL MITEL Fail bit 8 XL Framer Fail bit 9 XL DSP Fail For LRS52 - refer to product's spec When a bit is ('1'), the error exists. When NO ERROR is encountered, this object's value will be 0.