MIB Viewer

tcpServerMaxConnection

OBJECT-TYPE
1.3.6.1.4.1.8691.2.13.1.4.1.2.3.1.1.3
Access
read-write
Status
current
Sub-identifiers
0
Max connection is usually used when the user needs to receive data from different hosts simultaneously. The factory default is 1. In this case, only one specific host can access this port of the NPort W2x50A series device server, and the TCP server driver on that host will have full control over the port. Max. connection 1: Allows only a single host's to connect specific NPort W2x50A series device Max connection 2 to 8: Allows 2 to 8 hosts' to conncect NPort W2x50A series device at the same time.
INTEGER