MIB Viewer

x25CallParmEndTrnsDly

OBJECT-TYPE
1.3.6.1.2.1.10.5.9.1.24
Access
read-write
Status
mandatory
Sub-identifiers
0
The End-to-End Transit Delay to negotiate. An octet string of length 2, 4, or 6 contains the facility encoded as specified in ISO/IEC 8208 section 15.3.2.4. An octet string of length 3 containing the three character DEF for a circuit means use the PLE default (the entry for the PLE default can not contain the characters DEF). A zero length string indicates no facility requested.
OCTET STRING (SIZE(0..6))