MIB Viewer

xoiIfBrkSeqVar

OBJECT-TYPE
1.3.6.1.4.1.272.4.6.15.1.25
Access
read-write
Status
mandatory
Sub-identifiers
0
This object indicates the additional number of startbits to detect a break sequence send from V.110 terminal over an S2M interface. The default number of startbits is 22, you can vary this value in range from 12 to 32, configuring here -10 to 10.
INTEGER (-10..10)