MIB Viewer

zhoneVdslLineConfDownGinpReinFreq

OBJECT-TYPE
1.3.6.1.4.1.5504.5.13.1.1.11.1.152
Access
read-write
Status
current
Sub-identifiers
0
ginpReinFreq specifies the frequency of REIN inter-arrival time. It is used in the Channel Initialization Policy and on-line reconfiguration procedures. REIN is commonly coupled from electrical power cables appliances drawing power from the AC electrical power network, having a repetition rate of twice the AC power frequency (100 or 120 Hz). The valid values are integers 100 hz or 120 hz. ITU-T G.998.4 7.1.1 Control parameters and 7.1.2 Valid configurations.
INTEGER { freq100hz(1), freq120hz(2) }