EXTREME-POE-MIB
34 objects
Extreme Power over Ethernet MIB objects
Imported Objects
| EXTREME-BASE-MIB | extremeAgent extremeV2Traps |
| POWER-ETHERNET-MIB | pethMainPseGroupIndex pethPsePortGroupIndex pethPsePortIndex |
| SNMPv2-SMI | Counter32 Gauge32 Integer32 MODULE-IDENTITY NOTIFICATION-TYPE OBJECT-TYPE |
| SNMPv2-TC | TruthValue |
| OID | Name | Access | Status | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.1916.1.27 | IdentityextremePoE | Extreme Power over Ethernet MIB objects | ||
| 1.3.6.1.4.1.1916.1.27.1 | NodeextremePethMain | |||
| 1.3.6.1.4.1.1916.1.27.1.2 | TableextremePethPseSlotTable | not-accessible | current | A table of objects that provides power management capabilities per slot. |
| 1.3.6.1.4.1.1916.1.27.1.2.1 | RowextremePethPseSlotEntry | not-accessible | current | A set of objects that display and control the power characteristics of a slot. |
| 1.3.6.1.4.1.1916.1.27.1.2.1.1 | ColumnextremePethSlotNumber | not-accessible | current | Slot number. This is the same as the Group Index |
| 1.3.6.1.4.1.1916.1.27.1.2.1.2 | ColumnextremePethSlotPowerLimit | read-write | current | The configured maximum amount of inline power available to slot. The operational power available to the slot is based upon other operational and configuration … |
| 1.3.6.1.4.1.1916.1.27.1.2.1.3 | ColumnextremePethSlotConsumptionPower | read-only | current | The amount of power allocated to PoE devices on the slot expressed in Watts. The amount of power allocated to a PoE device is based upon the PoE device class a… |
| 1.3.6.1.4.1.1916.1.27.1.2.1.4 | ColumnextremePethSlotClearConnectHistory | read-write | current | Clears the port connection history of the specified slot. Reading the value always reurns clear(2). |
| 1.3.6.1.4.1.1916.1.27.1.2.1.5 | ColumnextremePethSlotReservedConsumptionPower | read-only | current | The amount of reserved power consumed on the slot expressed in Milliwatts. |
| 1.3.6.1.4.1.1916.1.27.1.2.1.6 | ColumnextremePethSlotCommonConsumptionPower | read-only | current | The amount of common power allocated on the slot expressed in Milliwatts. This value is computed by the formula: extremePethSlotConsumptionPower - extremePethS… |
| 1.3.6.1.4.1.1916.1.27.1.2.1.7 | ColumnextremePethSlotAdminEnable | read-write | current | Controls whether inline power is provided by the slot. |
| 1.3.6.1.4.1.1916.1.27.1.2.1.8 | ColumnextremePethSlotPoeStatus | read-only | current | Describes the status of the PoE system on the slot. initializing - PoE controller is under initialization, operational - PoE controller is operational and is r… |
| 1.3.6.1.4.1.1916.1.27.1.2.1.9 | ColumnextremePethSlotPoeResetSystem | read-write | current | Resets the PoE system on the slot. Reading returns clear(2) |
| 1.3.6.1.4.1.1916.1.27.1.2.1.10 | ColumnextremePethSlotMaxAvailPower | read-only | current | The maximum power available to the slot expressed in Watts. The value depends on various configuration parameters and power-supply modes and status. |
| 1.3.6.1.4.1.1916.1.27.1.2.1.11 | ColumnextremePethSlotMaxCapacity | read-only | current | The maximum capacity of the slot expressed in Watts. This provides the hardware limitation of the slot. Actual amount of power is dependant on system status. T… |
| 1.3.6.1.4.1.1916.1.27.1.2.1.12 | ColumnextremePethSlotBackupPSU | read-write | current | Controls the backup power supply for inline power for the slot. A system which does not allow the backup PSU to be configured will return an error upon setting. |
| 1.3.6.1.4.1.1916.1.27.1.2.1.13 | ColumnextremePethSlotPSUActive | read-only | current | Inline Power supply status indication for the slot. Indicates which PSU is currently active. In the case of a failover a none indication can occur until one of… |
| 1.3.6.1.4.1.1916.1.27.1.2.1.14 | ColumnextremePethSlotMeasuredPower | read-only | current | The measured amount of power for all PoE device on the slot. |
| 1.3.6.1.4.1.1916.1.27.1.2.1.15 | ColumnextremePethSlotMainPseIndex | read-only | current | The index into the PethMainPseTable. Provides the mapping of the slot identifier to pethMainPseGroupIndex. |
| 1.3.6.1.4.1.1916.1.27.2 | NodeextremePethPort | |||
| 1.3.6.1.4.1.1916.1.27.2.1 | TableextremePethPsePortTable | not-accessible | current | A table of objects that extends the standard pethPsePortTable. |
| 1.3.6.1.4.1.1916.1.27.2.1.1 | RowextremePethPsePortEntry | not-accessible | current | A set of objects that display and control the power characteristics of a powerEthernet PSE port. This table extends the standard pethPsePortTable. |
| 1.3.6.1.4.1.1916.1.27.2.1.1.1 | ColumnextremePethPortOperatorLimit | read-write | current | Controls individual port maximum power level. |
| 1.3.6.1.4.1.1916.1.27.2.1.1.2 | ColumnextremePethPortReservedBudget | read-write | current | Controls individual port maximum power level. Value is 0 or in the range of 3000..30000 |
| 1.3.6.1.4.1.1916.1.27.2.1.1.3 | ColumnextremePethPortViolationPrecedence | read-write | current | Sets the violation precedence for the specified ports. A value of advertised-class will remove/deny power in the case an 802.3af compliant PD consumes power be… |
| 1.3.6.1.4.1.1916.1.27.2.1.1.4 | ColumnextremePethPortClearFault | read-write | current | Clears the fault condition. Reading always returns clear(2). |
| 1.3.6.1.4.1.1916.1.27.2.1.1.5 | ColumnextremePethPortResetPower | read-write | current | Resets the power on the port. Reading always returns clear(2) |
| 1.3.6.1.4.1.1916.1.27.2.1.1.6 | ColumnextremePethPortMeasuredPower | read-only | current | The amount of power consumed on the port expressed in Milliwatts. |
| 1.3.6.1.4.1.1916.1.27.4 | NodeextremePethSystem | |||
| 1.3.6.1.4.1.1916.1.27.4.1 | ScalarextremePethSystemAdminEnable | read-write | current | Controls whether inline power is provided by the system. |
| 1.3.6.1.4.1.1916.1.27.4.2 | ScalarextremePethSystemDisconnectPrecedence | read-write | current | Controls the disconnect function of power management. When the power drain exceeds the available power budget, due to a rise in power consumption after power i… |
| 1.3.6.1.4.1.1916.1.27.4.3 | ScalarextremePethSystemUsageThreshold | read-write | current | The usage threshold expressed in percents for comparing the measured power and initiating an alarm if the threshold is exceeded. |
| 1.3.6.1.4.1.1916.1.27.4.4 | ScalarextremePethSystemPowerSupplyMode | read-write | current | Controls whether the power supply operate in redundant or load-sharing mode. Systems which do not provide redundant or load-sharing operations will return an e… |
| 1.3.6.1.4.1.1916.1.27.4.5 | ScalarextremePethSystemLegacyEnable | read-write | current | Controls whether legacy is supported by the system. This is only supported on S300-24 stackables currently. |