MIB Viewer

EXTREME-POE-MIB

34 objects
Extreme Power over Ethernet MIB objects
OIDNameAccessStatusDescription
1.3.6.1.4.1.1916.1.27IdentityextremePoEExtreme Power over Ethernet MIB objects
1.3.6.1.4.1.1916.1.27.1NodeextremePethMain
1.3.6.1.4.1.1916.1.27.1.2TableextremePethPseSlotTablenot-accessiblecurrentA table of objects that provides power management capabilities per slot.
1.3.6.1.4.1.1916.1.27.1.2.1RowextremePethPseSlotEntrynot-accessiblecurrentA set of objects that display and control the power characteristics of a slot.
1.3.6.1.4.1.1916.1.27.1.2.1.1ColumnextremePethSlotNumbernot-accessiblecurrentSlot number. This is the same as the Group Index
1.3.6.1.4.1.1916.1.27.1.2.1.2ColumnextremePethSlotPowerLimitread-writecurrentThe configured maximum amount of inline power available to slot. The operational power available to the slot is based upon other operational and configuration …
1.3.6.1.4.1.1916.1.27.1.2.1.3ColumnextremePethSlotConsumptionPowerread-onlycurrentThe amount of power allocated to PoE devices on the slot expressed in Watts. The amount of power allocated to a PoE device is based upon the PoE device class a…
1.3.6.1.4.1.1916.1.27.1.2.1.4ColumnextremePethSlotClearConnectHistoryread-writecurrentClears the port connection history of the specified slot. Reading the value always reurns clear(2).
1.3.6.1.4.1.1916.1.27.1.2.1.5ColumnextremePethSlotReservedConsumptionPowerread-onlycurrentThe amount of reserved power consumed on the slot expressed in Milliwatts.
1.3.6.1.4.1.1916.1.27.1.2.1.6ColumnextremePethSlotCommonConsumptionPowerread-onlycurrentThe amount of common power allocated on the slot expressed in Milliwatts. This value is computed by the formula: extremePethSlotConsumptionPower - extremePethS…
1.3.6.1.4.1.1916.1.27.1.2.1.7ColumnextremePethSlotAdminEnableread-writecurrentControls whether inline power is provided by the slot.
1.3.6.1.4.1.1916.1.27.1.2.1.8ColumnextremePethSlotPoeStatusread-onlycurrentDescribes the status of the PoE system on the slot. initializing - PoE controller is under initialization, operational - PoE controller is operational and is r…
1.3.6.1.4.1.1916.1.27.1.2.1.9ColumnextremePethSlotPoeResetSystemread-writecurrentResets the PoE system on the slot. Reading returns clear(2)
1.3.6.1.4.1.1916.1.27.1.2.1.10ColumnextremePethSlotMaxAvailPowerread-onlycurrentThe maximum power available to the slot expressed in Watts. The value depends on various configuration parameters and power-supply modes and status.
1.3.6.1.4.1.1916.1.27.1.2.1.11ColumnextremePethSlotMaxCapacityread-onlycurrentThe maximum capacity of the slot expressed in Watts. This provides the hardware limitation of the slot. Actual amount of power is dependant on system status. T…
1.3.6.1.4.1.1916.1.27.1.2.1.12ColumnextremePethSlotBackupPSUread-writecurrentControls the backup power supply for inline power for the slot. A system which does not allow the backup PSU to be configured will return an error upon setting.
1.3.6.1.4.1.1916.1.27.1.2.1.13ColumnextremePethSlotPSUActiveread-onlycurrentInline Power supply status indication for the slot. Indicates which PSU is currently active. In the case of a failover a none indication can occur until one of…
1.3.6.1.4.1.1916.1.27.1.2.1.14ColumnextremePethSlotMeasuredPowerread-onlycurrentThe measured amount of power for all PoE device on the slot.
1.3.6.1.4.1.1916.1.27.1.2.1.15ColumnextremePethSlotMainPseIndexread-onlycurrentThe index into the PethMainPseTable. Provides the mapping of the slot identifier to pethMainPseGroupIndex.
1.3.6.1.4.1.1916.1.27.2NodeextremePethPort
1.3.6.1.4.1.1916.1.27.2.1TableextremePethPsePortTablenot-accessiblecurrentA table of objects that extends the standard pethPsePortTable.
1.3.6.1.4.1.1916.1.27.2.1.1RowextremePethPsePortEntrynot-accessiblecurrentA set of objects that display and control the power characteristics of a powerEthernet PSE port. This table extends the standard pethPsePortTable.
1.3.6.1.4.1.1916.1.27.2.1.1.1ColumnextremePethPortOperatorLimitread-writecurrentControls individual port maximum power level.
1.3.6.1.4.1.1916.1.27.2.1.1.2ColumnextremePethPortReservedBudgetread-writecurrentControls individual port maximum power level. Value is 0 or in the range of 3000..30000
1.3.6.1.4.1.1916.1.27.2.1.1.3ColumnextremePethPortViolationPrecedenceread-writecurrentSets the violation precedence for the specified ports. A value of advertised-class will remove/deny power in the case an 802.3af compliant PD consumes power be…
1.3.6.1.4.1.1916.1.27.2.1.1.4ColumnextremePethPortClearFaultread-writecurrentClears the fault condition. Reading always returns clear(2).
1.3.6.1.4.1.1916.1.27.2.1.1.5ColumnextremePethPortResetPowerread-writecurrentResets the power on the port. Reading always returns clear(2)
1.3.6.1.4.1.1916.1.27.2.1.1.6ColumnextremePethPortMeasuredPowerread-onlycurrentThe amount of power consumed on the port expressed in Milliwatts.
1.3.6.1.4.1.1916.1.27.4NodeextremePethSystem
1.3.6.1.4.1.1916.1.27.4.1ScalarextremePethSystemAdminEnableread-writecurrentControls whether inline power is provided by the system.
1.3.6.1.4.1.1916.1.27.4.2ScalarextremePethSystemDisconnectPrecedenceread-writecurrentControls the disconnect function of power management. When the power drain exceeds the available power budget, due to a rise in power consumption after power i…
1.3.6.1.4.1.1916.1.27.4.3ScalarextremePethSystemUsageThresholdread-writecurrentThe usage threshold expressed in percents for comparing the measured power and initiating an alarm if the threshold is exceeded.
1.3.6.1.4.1.1916.1.27.4.4ScalarextremePethSystemPowerSupplyModeread-writecurrentControls whether the power supply operate in redundant or load-sharing mode. Systems which do not provide redundant or load-sharing operations will return an e…
1.3.6.1.4.1.1916.1.27.4.5ScalarextremePethSystemLegacyEnableread-writecurrentControls whether legacy is supported by the system. This is only supported on S300-24 stackables currently.