MIB Viewer

HUAWEI-COMMTEST-MIB

410 objects
This MIB is used for Metallic line test(MELT).Melt test is a common line status test method,used to test whether the copper twisted pair from the service board to the phone set is normal. Common MELT operations include starting a MELT test, querying the test result, querying the calibration data, and starting and stopping a searching tone test.
OIDNameAccessStatusDescription
1.3.6.1.4.1.2011.6.21NodehwTest
1.3.6.1.4.1.2011.6.21.1IdentityhwTestCommonThis MIB is used for Metallic line test(MELT).Melt test is a common line status test method,used to test whether the copper twisted pair from the service board…
1.3.6.1.4.1.2011.6.21.1.1NodehwTestCommonMib
1.3.6.1.4.1.2011.6.21.1.1.1NodehwTestCommonMIBObjects
1.3.6.1.4.1.2011.6.21.1.1.1.1TablehwTestGroupOprTablenot-accessiblecurrentTable of the test group: It provides the number of the test group to which a shelf of the device corresponds. It is uniquely identified by the number of the te…
1.3.6.1.4.1.2011.6.21.1.1.1.1.1RowhwTestGroupOprEntrynot-accessiblecurrentTable of the test group: It provides the number of the test group to which a shelf of the device corresponds. It is uniquely identified by the number of the te…
1.3.6.1.4.1.2011.6.21.1.1.1.1.1.1ColumnhwTestGroupNonot-accessiblecurrentTest group number. The MD5500 supports the number that ranges from 0 to 240. The MA5100 supports the number that ranges from 0 to 4. The MA5300 supports the nu…
1.3.6.1.4.1.2011.6.21.1.1.1.1.1.2ColumnhwTestBoardIfIndexread-createcurrentTest board IfIndex.
1.3.6.1.4.1.2011.6.21.1.1.1.1.1.3ColumnhwTestGroupAssistIfIndexread-createcurrentTestGroupAssist port IfIndex.
1.3.6.1.4.1.2011.6.21.1.1.1.1.1.4ColumnhwTestGroupAssistTelNoread-createcurrentAssistant telephone number. The maximum length is 16 Octets.
1.3.6.1.4.1.2011.6.21.1.1.1.1.1.5ColumnhwTestGroupRowStatusread-createcurrentPresent operation status of a row. Options: 1. active(1), -the present operation status of the row is active 2. notInService(2), -the present operation status …
1.3.6.1.4.1.2011.6.21.1.1.1.2TablehwLoopLineTestOprTablenot-accessiblecurrentThis table is used for enabling a subscriber line test and obtaining the test result after a test is complete. The subscriber line test function can be used fo…
1.3.6.1.4.1.2011.6.21.1.1.1.2.1RowhwLoopLineTestOprEntrynot-accessiblecurrentThis table is used for enabling a subscriber line test and obtaining the test result after a test is complete. The subscriber line test function can be used fo…
1.3.6.1.4.1.2011.6.21.1.1.1.2.1.1ColumnhwLoopLineTestOprTyperead-createcurrentMELT operation type Options: 1. stop(1) -stop a MELT test 2. start(2) -start a MELT test 3. invalid(-1) -invalid value
1.3.6.1.4.1.2011.6.21.1.1.1.2.1.2ColumnhwLoopLineTestVoltageread-createcurrentIndicates whether a voltage exists on the line under test. Options: 1. notest(1) -the voltage does not exist on the line under test 2. test(2) -the voltage exi…
1.3.6.1.4.1.2011.6.21.1.1.1.2.1.3ColumnhwLoopLineTestResistanceread-createcurrentIndicates whether resistance exists on the line under test. Options: 1. notest(1) -resistance does not exist on the line under test 2. test(2) -resistance exis…
1.3.6.1.4.1.2011.6.21.1.1.1.2.1.4ColumnhwLoopLineTestCapacitanceread-createcurrentIndicates whether capacitance exists on the line under test. Options: 1. notest(1) -capacitance does not exist on the line under test 2. test(2) -capacitance e…
1.3.6.1.4.1.2011.6.21.1.1.1.2.1.5ColumnhwLoopLineTestLoopResistanceread-createcurrentIndicates whether loop resistance exists on the line under test. Options: 1. notest(1) -loop resistance does not exist on the line under test 2. test(2) -loop …
1.3.6.1.4.1.2011.6.21.1.1.1.2.1.6ColumnhwLoopLineTestPoleResistanceread-createcurrentIndicates whether pole resistance exists on the line under test. Options: 1. notest(1) -Pole resistance does not exist on the line under test 2. test(2) -Pole …
1.3.6.1.4.1.2011.6.21.1.1.1.2.1.7ColumnhwLoopLineTestBusyProcFlagread-createcurrentIdentify whether to start a test when the line is busy. The system will excecute a corresponding operation according to the configuration that a user specifies…
1.3.6.1.4.1.2011.6.21.1.1.1.2.1.8ColumnhwLoopLineTestStatusread-onlycurrentIndicates the result of MELT test. Options: 1. normal(1) -the MELT test is successful 2. testFail(2) -the MELT test fails 3. portBusy(3) -the MELT test port is…
1.3.6.1.4.1.2011.6.21.1.1.1.2.1.9ColumnhwLoopLineTestConclusionread-onlycurrentMELT test conclusion, this object is for pots and combo board's port. Options: 1. normal(1) -the test conclusion is normal 2. meetLine(2) -the test conclusion …
1.3.6.1.4.1.2011.6.21.1.1.1.2.1.10ColumnhwLoopLineTestACAGread-onlycurrentIndicates the A->ground AC voltage. Unit: mV
1.3.6.1.4.1.2011.6.21.1.1.1.2.1.11ColumnhwLoopLineTestACBGread-onlycurrentIndicates the B->ground AC voltage. Unit: mV
1.3.6.1.4.1.2011.6.21.1.1.1.2.1.12ColumnhwLoopLineTestACABread-onlycurrentIndicates the A->B AC voltage. Unit: mV
1.3.6.1.4.1.2011.6.21.1.1.1.2.1.13ColumnhwLoopLineTestDCAGread-onlycurrentIndicates the A->ground DC voltage. Unit: mV
1.3.6.1.4.1.2011.6.21.1.1.1.2.1.14ColumnhwLoopLineTestDCBGread-onlycurrentIndicates the B->ground DC voltage. Unit: mV
1.3.6.1.4.1.2011.6.21.1.1.1.2.1.15ColumnhwLoopLineTestDCABread-onlycurrentIndicates the A->B DC voltage. Unit: mV
1.3.6.1.4.1.2011.6.21.1.1.1.2.1.16ColumnhwLoopLineTestRAGread-onlycurrentIndicates the A->ground insulation resistance. Unit: ohm
1.3.6.1.4.1.2011.6.21.1.1.1.2.1.17ColumnhwLoopLineTestRBGread-onlycurrentIndicates the B->ground insulation resistance. Unit: ohm
1.3.6.1.4.1.2011.6.21.1.1.1.2.1.18ColumnhwLoopLineTestRABread-onlycurrentIndicates the A->B insulation resistance. Unit: ohm
1.3.6.1.4.1.2011.6.21.1.1.1.2.1.19ColumnhwLoopLineTestCapAGread-onlycurrentIndicates the A->ground capacitance. Unit: nF
1.3.6.1.4.1.2011.6.21.1.1.1.2.1.20ColumnhwLoopLineTestCapBGread-onlycurrentIndicates the B->ground capacitance. Unit: nF
1.3.6.1.4.1.2011.6.21.1.1.1.2.1.21ColumnhwLoopLineTestCapABread-onlycurrentIndicates the A->B capacitance. Unit: nF
1.3.6.1.4.1.2011.6.21.1.1.1.2.1.22ColumnhwLoopLineTestLRread-onlycurrentIndicates the loop resistance. Unit: ohm
1.3.6.1.4.1.2011.6.21.1.1.1.2.1.23ColumnhwLoopLineTestRABResPoleread-onlycurrentIndicates the A->B polarity reversal resistance. Unit: ohm
1.3.6.1.4.1.2011.6.21.1.1.1.2.1.24ColumnhwLoopLineTestMSocketread-onlycurrentIndicates the M-socket connection. Options: 1. notconnected(1) -the M-socket is not connected 2. connected(2) -the M-socket is connected 3. aBReversed(3) -the …
1.3.6.1.4.1.2011.6.21.1.1.1.2.1.25ColumnhwLoopLineTestBtssPowerProcFlagread-createcurrentLoop line test-BTSS line with power processing. Options: 1. noTest(1) -not test 2. test(2) -test 3. invalid(-1) -invalid value
1.3.6.1.4.1.2011.6.21.1.1.1.2.1.26ColumnhwLoopLineTestImpedanceread-createcurrentLoop line test-impedance. Options: 1. notest(1) -not test 2. test(2) -test
1.3.6.1.4.1.2011.6.21.1.1.1.2.1.27ColumnhwLoopLineTestImpedanceABread-onlycurrentA->B impedance (unit: ohm)
1.3.6.1.4.1.2011.6.21.1.1.1.2.1.28ColumnhwLoopLineTestImpedanceBAread-onlycurrentB->A impedance (unit: ohm)
1.3.6.1.4.1.2011.6.21.1.1.1.2.1.29ColumnhwLoopLineTestImpedanceAGread-onlycurrentA->ground impedance (unit: ohm)
1.3.6.1.4.1.2011.6.21.1.1.1.2.1.30ColumnhwLoopLineTestImpedanceBGread-onlycurrentB->ground impedance (unit: ohm)
1.3.6.1.4.1.2011.6.21.1.1.1.2.1.31ColumnhwLoopLineTestCurrentread-createcurrentLoop line test-current. Options: 1. notest(1) -not test 2. test(2) -test
1.3.6.1.4.1.2011.6.21.1.1.1.2.1.32ColumnhwLoopLineTestACCurrentAGread-onlycurrentA->ground AC current (unit: mA)
1.3.6.1.4.1.2011.6.21.1.1.1.2.1.33ColumnhwLoopLineTestACCurrentBGread-onlycurrentB->ground AC current (unit: mA)
1.3.6.1.4.1.2011.6.21.1.1.1.2.1.34ColumnhwLoopLineTestACCurrentABread-onlycurrentAB AC current (unit: mA)
1.3.6.1.4.1.2011.6.21.1.1.1.2.1.35ColumnhwLoopLineTestDCCurrentAGread-onlycurrentA->ground DC current (unit: mA)
1.3.6.1.4.1.2011.6.21.1.1.1.2.1.36ColumnhwLoopLineTestDCCurrentBGread-onlycurrentB->ground DC current (unit: mA)
1.3.6.1.4.1.2011.6.21.1.1.1.2.1.37ColumnhwLoopLineTestDCCurrentABread-onlycurrentAB DC current (unit: mA)
1.3.6.1.4.1.2011.6.21.1.1.1.2.1.38ColumnhwLoopLineTestLoopCurrentread-createcurrentLoop line test-loop current. Options: 1. notest(1) -not test 2. test(2) -test
1.3.6.1.4.1.2011.6.21.1.1.1.2.1.39ColumnhwLoopLineTestLCread-onlycurrentLoop current (unit: uA)
1.3.6.1.4.1.2011.6.21.1.1.1.2.1.40ColumnhwLoopLineTestNoiseread-createcurrentLoop line test-noise. Options: 1. notest(1) -not test 2. test(2) -test
1.3.6.1.4.1.2011.6.21.1.1.1.2.1.41ColumnhwLoopLineTestNread-onlycurrentNoise (unit: dBm)
1.3.6.1.4.1.2011.6.21.1.1.1.2.1.42ColumnhwLoopLineTestPPAread-createcurrentIndicates whether PPA exists on the line under test. Options: 1. notest(1) -PPA does not exist on the line under test 2. test(2) -PPA exists on the line under …
1.3.6.1.4.1.2011.6.21.1.1.1.2.1.43ColumnhwLoopLineTestPPAResultread-onlycurrentIndicates whether the PPA exists. Options: 1. noexist(1) -PPA does not exist 2. exist(2) -PPA exists 3. inverseexist(3) -PPA inverse exists 4. invalid(-1) -inv…
1.3.6.1.4.1.2011.6.21.1.1.1.2.1.44ColumnhwLoopLineTestDeferredTimeread-createcurrentIndicates the deferred time. Unit: minute This leaf is valid only when the value of hwLoopLineTestBusyProcFlag is DeferredTest(4). Default: 30
1.3.6.1.4.1.2011.6.21.1.1.1.2.1.45ColumnhwLoopLineTestTimeoutProcread-createcurrentIndicates the timeout processing. Options: 1. notest(1) -if the deferred time times out and the port is still busy the test will be canceled 2. test(2) -if the…
1.3.6.1.4.1.2011.6.21.1.1.1.2.1.46ColumnhwLoopLineTestReverseread-createcurrentReverse flag (0:normal test 1:reverse test)
1.3.6.1.4.1.2011.6.21.1.1.1.2.1.47ColumnhwLoopLineTestUtgAcFreqread-onlycurrentFrequency of foreign AC voltage source coupled to tip via Zbat_tip impedance. Unit: Hz
1.3.6.1.4.1.2011.6.21.1.1.1.2.1.48ColumnhwLoopLineTestUrgAcFreqread-onlycurrentFrequency of foreign AC voltage source coupled to ring via Zbat_ring impedance. Unit:Hz
1.3.6.1.4.1.2011.6.21.1.1.1.2.1.49ColumnhwLoopLineTestUtrAcFreqread-onlycurrentFrequency of foreign AC voltage source coupled to tip-ring via Zbat_tipring impedance. Unit:Hz
1.3.6.1.4.1.2011.6.21.1.1.1.2.1.50ColumnhwLoopLineTestItipAcread-onlycurrentAC foreign current on the tip wire. Unit:uA
1.3.6.1.4.1.2011.6.21.1.1.1.2.1.51ColumnhwLoopLineTestIringAcread-onlycurrentAC foreign current on the ring wire. Unit:uA
1.3.6.1.4.1.2011.6.21.1.1.1.2.1.52ColumnhwLoopLineTestItipDcread-onlycurrentDC foreign current on the tip wire. Unit:uA
1.3.6.1.4.1.2011.6.21.1.1.1.2.1.53ColumnhwLoopLineTestIringDcread-onlycurrentDC foreign current on the ring wire. Unit:uA
1.3.6.1.4.1.2011.6.21.1.1.1.2.1.54ColumnhwLoopLineTestRbattipread-onlycurrentIn presence of a foreign voltage, the equivalent coupling resistance of wire A. Unit:ohm
1.3.6.1.4.1.2011.6.21.1.1.1.2.1.55ColumnhwLoopLineTestRbatringread-onlycurrentIn presence of a foreign voltage, the equivalent coupling resistance of wire B. Unit:ohm
1.3.6.1.4.1.2011.6.21.1.1.1.2.1.56ColumnhwLoopLineTestRringread-onlycurrentResistance in series with the ring capacitance, for example when a ringer load or a passive R-C signature terminates the loop. It also includes the cable resis…
1.3.6.1.4.1.2011.6.21.1.1.1.2.1.57ColumnhwLoopLineTestCsigread-onlycurrentCapacitance of an xDSL signal. Unit: nF
1.3.6.1.4.1.2011.6.21.1.1.1.2.1.58ColumnhwLoopLineTestVzenerread-onlycurrentZener diode threshold in the case of an off-hook phone. Unit: mV
1.3.6.1.4.1.2011.6.21.1.1.1.2.1.59ColumnhwLoopLineTestRzenerread-onlycurrentDC tip-ring resistance measured in the case of an off-hook phone. Unit: ohm
1.3.6.1.4.1.2011.6.21.1.1.1.2.1.60ColumnhwLoopLineTestGtgread-onlycurrentAggregate a->ground conductance. Unit: nS
1.3.6.1.4.1.2011.6.21.1.1.1.2.1.61ColumnhwLoopLineTestBtgread-onlycurrentAggregate a->ground susceptance. Unit: nS
1.3.6.1.4.1.2011.6.21.1.1.1.2.1.62ColumnhwLoopLineTestGrgread-onlycurrentAggregate b->ground conductance. Unit: nS
1.3.6.1.4.1.2011.6.21.1.1.1.2.1.63ColumnhwLoopLineTestBrgread-onlycurrentAggregate b->ground susceptance. Unit: nS
1.3.6.1.4.1.2011.6.21.1.1.1.2.1.64ColumnhwLoopLineTestGtrread-onlycurrentAggregate a->b conductance. Unit: nS
1.3.6.1.4.1.2011.6.21.1.1.1.2.1.65ColumnhwLoopLineTestBtrread-onlycurrentAggregate a->b susceptance. Unit: nS
1.3.6.1.4.1.2011.6.21.1.1.1.2.1.66ColumnhwLoopLineTestSIGNread-onlycurrentIndicates the ETSI xDSL Signature is detected or not.
1.3.6.1.4.1.2011.6.21.1.1.1.2.1.67ColumnhwLoopLineTestACFEMread-onlycurrentIndicates the presence of an AC foreign voltage above the threshold defined by ACFEMmin. By reading the results of the foreign voltage test, it is possible to …
1.3.6.1.4.1.2011.6.21.1.1.1.2.1.68ColumnhwLoopLineTestDCFEMread-onlycurrentIndicates the presence of a DC foreign voltage above the threshold defined by DCFEMmin. By reading the results of the foreign voltage test, it is possible to d…
1.3.6.1.4.1.2011.6.21.1.1.1.2.1.69ColumnhwLoopLineTestONHKread-onlycurrentIndicates the presens of a phone in the on-hook state.
1.3.6.1.4.1.2011.6.21.1.1.1.2.1.70ColumnhwLoopLineTestOPENread-onlycurrentIndicates a->b resistance exceeds the threshold.
1.3.6.1.4.1.2011.6.21.1.1.1.2.1.71ColumnhwLoopLineTestSHORTread-onlycurrentIndicates that the insulation resistance is small.
1.3.6.1.4.1.2011.6.21.1.1.1.2.1.72ColumnhwLoopLineTestROHread-onlycurrentIndicates a phone in the off-hook state.
1.3.6.1.4.1.2011.6.21.1.1.1.2.1.73ColumnhwLoopLineTestUtgDcUpread-onlycurrentIndicates the a->ground highest measurement DC voltage. Unit: mV
1.3.6.1.4.1.2011.6.21.1.1.1.2.1.74ColumnhwLoopLineTestUtgDcDownread-onlycurrentIndicates the a->ground lowest measurement DC voltage. Unit: mV
1.3.6.1.4.1.2011.6.21.1.1.1.2.1.75ColumnhwLoopLineTestUrgDcUpread-onlycurrentIndicates the b->ground highest measurement DC voltage. Unit: mV
1.3.6.1.4.1.2011.6.21.1.1.1.2.1.76ColumnhwLoopLineTestUrgDcDownread-onlycurrentIndicates the b->ground lowest measurement DC voltage. Unit: mV
1.3.6.1.4.1.2011.6.21.1.1.1.2.1.77ColumnhwLoopLineTestUtrPosread-onlycurrentIndicates the a->b positive measurement DC voltage. Unit: mV
1.3.6.1.4.1.2011.6.21.1.1.1.2.1.78ColumnhwLoopLineTestUtrNegread-onlycurrentIndicates the b->a measurement DC voltage. Unit: mV
1.3.6.1.4.1.2011.6.21.1.1.1.2.1.79ColumnhwLoopLineTestItgDcUpread-onlycurrentIndicates the current mapping the A-wire highest voltage for test. Unit: uA
1.3.6.1.4.1.2011.6.21.1.1.1.2.1.80ColumnhwLoopLineTestItgDcDownread-onlycurrentIndicates the current mapping the A-wire lowest voltage for test. Unit: uA
1.3.6.1.4.1.2011.6.21.1.1.1.2.1.81ColumnhwLoopLineTestIrgDcUpread-onlycurrentIndicates the current mapping the B-wire highest voltage for test. Unit: uA
1.3.6.1.4.1.2011.6.21.1.1.1.2.1.82ColumnhwLoopLineTestIrgDcDownread-onlycurrentIndicates the current mapping the B-wire lowest voltage for test. Unit: uA
1.3.6.1.4.1.2011.6.21.1.1.1.2.1.83ColumnhwLoopLineTestItrPosread-onlycurrentIndicates the current mapping the A->B positive voltage for test. Unit: uA
1.3.6.1.4.1.2011.6.21.1.1.1.2.1.84ColumnhwLoopLineTestItrNegread-onlycurrentIndicates the current mapping the A->B negative voltage for test. Unit: uA
1.3.6.1.4.1.2011.6.21.1.1.1.2.1.85ColumnhwLoopLineTestRingerread-onlycurrentIndicates the detected ringer.
1.3.6.1.4.1.2011.6.21.1.1.1.2.1.86ColumnhwLoopLineTestPPAResread-onlycurrentIndicates the resistance of PPA. Unit: ohm
1.3.6.1.4.1.2011.6.21.1.1.1.2.1.87ColumnhwLoopLineTestStartTimeread-onlycurrentIndicates the start time and date of the MELT test.
1.3.6.1.4.1.2011.6.21.1.1.1.2.1.88ColumnhwLoopLineTestEndTimeread-onlycurrentIndicates the end time and date of the MELT test.
1.3.6.1.4.1.2011.6.21.1.1.1.2.1.89ColumnhwLoopLineTestOprMeasuredFreqread-writecurrentIndicates the measured frequency for complex impedance. Options: 1. frequency25Hz(0) -25 Hz 2. frequency275Hz(1) -275 Hz 3. invalid(-1) -invalid value Default:…
1.3.6.1.4.1.2011.6.21.1.1.1.2.1.90ColumnhwLoopLineTestIfIndexread-onlycurrentPort IfIndex.
1.3.6.1.4.1.2011.6.21.1.1.1.2.1.91ColumnhwLoopLineTestRequestIDread-onlycurrentRequest ID. The value is the fourth parameter in the trap message.
1.3.6.1.4.1.2011.6.21.1.1.1.2.1.92ColumnhwLoopLineTestRABPoleread-onlycurrentIndicates the A->B polarity resistance. Unit: ohm
1.3.6.1.4.1.2011.6.21.1.1.1.2.1.93ColumnhwLoopLineTestACAGFlagread-onlycurrentIndicates whether the value of hwLoopLineTestACAG is valid. Options: 1. valid(1) -the value of hwLoopLineTestACAG is valid 2. invalid(2) -the value of hwLoopLi…
1.3.6.1.4.1.2011.6.21.1.1.1.2.1.94ColumnhwLoopLineTestACBGFlagread-onlycurrentIndicates whether the value of hwLoopLineTestACBG is valid. Options: 1. valid(1) -the value of hwLoopLineTestACBG is valid 2. invalid(2) -the value of hwLoopLi…
1.3.6.1.4.1.2011.6.21.1.1.1.2.1.95ColumnhwLoopLineTestACABFlagread-onlycurrentIndicates whether the value of hwLoopLineTestACAB is valid. Options: 1. valid(1) -the value of hwLoopLineTestACAB is valid 2. invalid(2) -the value of hwLoopLi…
1.3.6.1.4.1.2011.6.21.1.1.1.2.1.96ColumnhwLoopLineTestDCAGFlagread-onlycurrentIndicates whether the value of hwLoopLineTestDCAG is valid. Options: 1. valid(1) -the value of hwLoopLineTestDCAG is valid 2. invalid(2) -the value of hwLoopLi…
1.3.6.1.4.1.2011.6.21.1.1.1.2.1.97ColumnhwLoopLineTestDCBGFlagread-onlycurrentIndicates whether the value of hwLoopLineTestDCBG is valid. Options: 1. valid(1) -the value of hwLoopLineTestDCBG is valid 2. invalid(2) -the value of hwLoopLi…
1.3.6.1.4.1.2011.6.21.1.1.1.2.1.98ColumnhwLoopLineTestDCABFlagread-onlycurrentIndicates whether the value of hwLoopLineTestDCAB is valid. Options: 1. valid(1) -the value of hwLoopLineTestDCAB is valid 2. invalid(2) -the value of hwLoopLi…
1.3.6.1.4.1.2011.6.21.1.1.1.2.1.99ColumnhwLoopLineTestRAGFlagread-onlycurrentIndicates whether the value of hwLoopLineTestRAG is valid. Options: 1. valid(1) -the value of hwLoopLineTestRAG is valid 2. invalid(2) -the value of hwLoopLine…
1.3.6.1.4.1.2011.6.21.1.1.1.2.1.100ColumnhwLoopLineTestRBGFlagread-onlycurrentIndicates whether the value of hwLoopLineTestRBG is valid. Options: 1. valid(1) -the value of hwLoopLineTestRBG is valid 2. invalid(2) -the value of hwLoopLine…
1.3.6.1.4.1.2011.6.21.1.1.1.2.1.101ColumnhwLoopLineTestRABFlagread-onlycurrentIndicates whether the value of hwLoopLineTestRAB is valid. Options: 1. valid(1) -the value of hwLoopLineTestRAB is valid 2. invalid(2) -the value of hwLoopLine…
1.3.6.1.4.1.2011.6.21.1.1.1.2.1.102ColumnhwLoopLineTestRABPoleFlagread-onlycurrentIndicates whether the value of hwLoopLineTestRABPole is valid. Options: 1. valid(1) -the value of hwLoopLineTestRABPole is valid 2. invalid(2) -the value of hw…
1.3.6.1.4.1.2011.6.21.1.1.1.2.1.103ColumnhwLoopLineTestRABResPoleFlagread-onlycurrentIndicates whether the value of hwLoopLineTestRABResPole is valid. Options: 1. valid(1) -the value of hwLoopLineTestRABResPole is valid 2. invalid(2) -the value…
1.3.6.1.4.1.2011.6.21.1.1.1.2.1.104ColumnhwLoopLineTestCapAGFlagread-onlycurrentIndicates whether the value of hwLoopLineTestCapAG is valid. Options: 1. valid(1) -the value of hwLoopLineTestCapAG is valid 2. invalid(2) -the value of hwLoop…
1.3.6.1.4.1.2011.6.21.1.1.1.2.1.105ColumnhwLoopLineTestCapBGFlagread-onlycurrentIndicates whether the value of hwLoopLineTestCapBG is valid. Options: 1. valid(1) -the value of hwLoopLineTestCapBG is valid 2. invalid(2) -the value of hwLoop…
1.3.6.1.4.1.2011.6.21.1.1.1.2.1.106ColumnhwLoopLineTestCapABFlagread-onlycurrentIndicates whether the value of hwLoopLineTestCapAB is valid. Options: 1. valid(1) -the value of hwLoopLineTestCapAB is valid 2. invalid(2) -the value of hwLoop…
1.3.6.1.4.1.2011.6.21.1.1.1.2.1.107ColumnhwLoopLineTestRbattipFlagread-onlycurrentIndicates whether the value of hwLoopLineTestRbattip is valid. Options: 1. valid(1) -the value of hwLoopLineTestRbattip is valid 2. invalid(2) -the value of hw…
1.3.6.1.4.1.2011.6.21.1.1.1.2.1.108ColumnhwLoopLineTestRbatringFlagread-onlycurrentIndicates whether the value of hwLoopLineTestRbatring is valid. Options: 1. valid(1) -the value of hwLoopLineTestRbatring is valid 2. invalid(2) -the value of …
1.3.6.1.4.1.2011.6.21.1.1.1.2.1.109ColumnhwLoopLineTestRringFlagread-onlycurrentIndicates whether the value of hwLoopLineTestRring is valid. Options: 1. valid(1) -the value of hwLoopLineTestRring is valid 2. invalid(2) -the value of hwLoop…
1.3.6.1.4.1.2011.6.21.1.1.1.2.1.110ColumnhwLoopLineTestCsigFlagread-onlycurrentIndicates whether the value of hwLoopLineTestCsig is valid. Options: 1. valid(1) -the value of hwLoopLineTestCsig is valid 2. invalid(2) -the value of hwLoopLi…
1.3.6.1.4.1.2011.6.21.1.1.1.2.1.111ColumnhwLoopLineTestPPAResFlagread-onlycurrentIndicates whether the value of hwLoopLineTestPPARes is valid. Options: 1. valid(1) -the value of hwLoopLineTestPPARes is valid 2. invalid(2) -the value of hwLo…
1.3.6.1.4.1.2011.6.21.1.1.1.2.1.112ColumnhwLoopLineTestVzenerFlagread-onlycurrentIndicates whether the value of hwLoopLineTestVzener is valid. Options: 1. valid(1) -the value of hwLoopLineTestVzener is valid 2. invalid(2) -the value of hwLo…
1.3.6.1.4.1.2011.6.21.1.1.1.2.1.113ColumnhwLoopLineTestRzenerFlagread-onlycurrentIndicates whether the value of hwLoopLineTestRzener is valid. Options: 1. valid(1) -the value of hwLoopLineTestRzener is valid 2. invalid(2) -the value of hwLo…
1.3.6.1.4.1.2011.6.21.1.1.1.2.1.114ColumnhwLoopLineTestSNMPRabread-onlycurrentIndicates the A to B resistance (insulation resistance). Unit: ohm
1.3.6.1.4.1.2011.6.21.1.1.1.2.1.115ColumnhwLoopLineTestSNMPRabFlagread-onlycurrentIndicates whether the value of hwLoopLineTestSNMPRab is valid. Options: 1. valid(1) -the value of hwLoopLineTestSNMPRab is valid 2. invalid(2) -the value of hw…
1.3.6.1.4.1.2011.6.21.1.1.1.2.1.116ColumnhwLoopLineTestSNMPRbaread-onlycurrentIndicates the B to A resistance (insulation resistance). Unit: ohm
1.3.6.1.4.1.2011.6.21.1.1.1.2.1.117ColumnhwLoopLineTestSNMPRbaFlagread-onlycurrentIndicates whether the value of hwLoopLineTestSNMPRba is valid. Options: 1. valid(1) -the value of hwLoopLineTestSNMPRba is valid 2. invalid(2) -the value of hw…
1.3.6.1.4.1.2011.6.21.1.1.1.2.1.118ColumnhwLoopLineTestPPAResultFlagread-onlycurrentIndicates whether the value of hwLoopLineTestPPA is valid. Options: 1. valid(1) -the value of hwLoopLineTestPPA is valid 2. invalid(2) -the value of hwLoopLine…
1.3.6.1.4.1.2011.6.21.1.1.1.2.1.119ColumnhwLoopLineTestUtgAcFreqFlagread-onlycurrentIndicates whether the value of hwLoopLineTestUtgAcFreq is valid. Options: 1. valid(1) -the value of hwLoopLineTestUtgAcFreq is valid 2. invalid(2) -the value o…
1.3.6.1.4.1.2011.6.21.1.1.1.2.1.120ColumnhwLoopLineTestUrgAcFreqFlagread-onlycurrentIndicates whether the value of hwLoopLineTestUrgAcFreq is valid. Options: 1. valid(1) -the value of hwLoopLineTestUrgAcFreq is valid 2. invalid(2) -the value o…
1.3.6.1.4.1.2011.6.21.1.1.1.2.1.121ColumnhwLoopLineTestUtrAcFreqFlagread-onlycurrentIndicates whether the value of hwLoopLineTestUtrAcFreq is valid. Options: 1. valid(1) -the value of hwLoopLineTestUtrAcFreq is valid 2. invalid(2) -the value o…
1.3.6.1.4.1.2011.6.21.1.1.1.2.1.122ColumnhwLoopLineTestItipAcFlagread-onlycurrentIndicates whether the value of hwLoopLineTestItipAc is valid. Options: 1. valid(1) -the value of hwLoopLineTestItipAc is valid 2. invalid(2) -the value of hwLo…
1.3.6.1.4.1.2011.6.21.1.1.1.2.1.123ColumnhwLoopLineTestIringAcFlagread-onlycurrentIndicates whether the value of hwLoopLineTestIringAc is valid. Options: 1. valid(1) -the value of hwLoopLineTestIringAc is valid 2. invalid(2) -the value of hw…
1.3.6.1.4.1.2011.6.21.1.1.1.2.1.124ColumnhwLoopLineTestItipDcFlagread-onlycurrentIndicates whether the value of hwLoopLineTestItipDc is valid. Options: 1. valid(1) -the value of hwLoopLineTestItipDc is valid 2. invalid(2) -the value of hwLo…
1.3.6.1.4.1.2011.6.21.1.1.1.2.1.125ColumnhwLoopLineTestIringDcFlagread-onlycurrentIndicates whether the value of hwLoopLineTestIringDc is valid. Options: 1. valid(1) -the value of hwLoopLineTestIringDc is valid 2. invalid(2) -the value of hw…
1.3.6.1.4.1.2011.6.21.1.1.1.2.1.126ColumnhwLoopLineTestGtgFlagread-onlycurrentIndicates whether the value of hwLoopLineTestGtg is valid. Options: 1. valid(1) -the value of hwLoopLineTestGtg is valid 2. invalid(2) -the value of hwLoopLine…
1.3.6.1.4.1.2011.6.21.1.1.1.2.1.127ColumnhwLoopLineTestBtgFlagread-onlycurrentIndicates whether the value of hwLoopLineTestBtg is valid. Options: 1. valid(1) -the value of hwLoopLineTestBtg is valid 2. invalid(2) -the value of hwLoopLine…
1.3.6.1.4.1.2011.6.21.1.1.1.2.1.128ColumnhwLoopLineTestGrgFlagread-onlycurrentIndicates whether the value of hwLoopLineTestGrg is valid. Options: 1. valid(1) -the value of hwLoopLineTestGrg is valid 2. invalid(2) -the value of hwLoopLine…
1.3.6.1.4.1.2011.6.21.1.1.1.2.1.129ColumnhwLoopLineTestBrgFlagread-onlycurrentIndicates whether the value of hwLoopLineTestBrg is valid. Options: 1. valid(1) -the value of hwLoopLineTestBrg is valid 2. invalid(2) -the value of hwLoopLine…
1.3.6.1.4.1.2011.6.21.1.1.1.2.1.130ColumnhwLoopLineTestGtrFlagread-onlycurrentIndicates whether the value of hwLoopLineTestGtr is valid. Options: 1. valid(1) -the value of hwLoopLineTestGtr is valid 2. invalid(2) -the value of hwLoopLine…
1.3.6.1.4.1.2011.6.21.1.1.1.2.1.131ColumnhwLoopLineTestBtrFlagread-onlycurrentIndicates whether the value of hwLoopLineTestBtr is valid. Options: 1. valid(1) -the value of hwLoopLineTestBtr is valid 2. invalid(2) -the value of hwLoopLine…
1.3.6.1.4.1.2011.6.21.1.1.1.2.1.132ColumnhwLoopLineTestSIGNFlagread-onlycurrentIndicates whether the value of hwLoopLineTestSIGN is valid. Options: 1. valid(1) -the value of hwLoopLineTestSIGN is valid 2. invalid(2) -the value of hwLoopLi…
1.3.6.1.4.1.2011.6.21.1.1.1.2.1.133ColumnhwLoopLineTestACFEMFlagread-onlycurrentIndicates whether the value of hwLoopLineTestACFEM is valid. Options: 1. valid(1) -the value of hwLoopLineTestACFEM is valid 2. invalid(2) -the value of hwLoop…
1.3.6.1.4.1.2011.6.21.1.1.1.2.1.134ColumnhwLoopLineTestDCFEMFlagread-onlycurrentIndicates whether the value of hwLoopLineTestDCFEM is valid. Options: 1. valid(1) -the value of hwLoopLineTestDCFEM is valid 2. invalid(2) -the value of hwLoop…
1.3.6.1.4.1.2011.6.21.1.1.1.2.1.135ColumnhwLoopLineTestONHKFlagread-onlycurrentIndicates whether the value of hwLoopLineTestONHK is valid. Options: 1. valid(1) -the value of hwLoopLineTestONHK is valid 2. invalid(2) -the value of hwLoopLi…
1.3.6.1.4.1.2011.6.21.1.1.1.2.1.136ColumnhwLoopLineTestOPENFlagread-onlycurrentIndicates whether the value of hwLoopLineTestOPEN is valid. Options: 1. valid(1) -the value of hwLoopLineTestOPEN is valid 2. invalid(2) -the value of hwLoopLi…
1.3.6.1.4.1.2011.6.21.1.1.1.2.1.137ColumnhwLoopLineTestSHORTFlagread-onlycurrentIndicates whether the value of hwLoopLineTestSHORT is valid. Options: 1. valid(1) -the value of hwLoopLineTestSHORT is valid 2. invalid(2) -the value of hwLoop…
1.3.6.1.4.1.2011.6.21.1.1.1.2.1.138ColumnhwLoopLineTestROHFlagread-onlycurrentIndicates whether the value of hwLoopLineTestROH is valid. Options: 1. valid(1) -the value of hwLoopLineTestROH is valid 2. invalid(2) -the value of hwLoopLine…
1.3.6.1.4.1.2011.6.21.1.1.1.2.1.139ColumnhwLoopLineTestUtgDcUpFlagread-onlycurrentIndicates whether the value of hwLoopLineTestUtgDcUp is valid. Options: 1. valid(1) -the value of hwLoopLineTestUtgDcUp is valid 2. invalid(2) -the value of hw…
1.3.6.1.4.1.2011.6.21.1.1.1.2.1.140ColumnhwLoopLineTestUtgDcDownFlagread-onlycurrentIndicates whether the value of hwLoopLineTestUtgDcDown is valid. Options: 1. valid(1) -the value of hwLoopLineTestUtgDcDown is valid 2. invalid(2) -the value o…
1.3.6.1.4.1.2011.6.21.1.1.1.2.1.141ColumnhwLoopLineTestUrgDcUpFlagread-onlycurrentIndicates whether the value of hwLoopLineTestUrgDcUp is valid. Options: 1. valid(1) -the value of hwLoopLineTestUrgDcUp is valid 2. invalid(2) -the value of hw…
1.3.6.1.4.1.2011.6.21.1.1.1.2.1.142ColumnhwLoopLineTestUrgDcDownFlagread-onlycurrentIndicates whether the value of hwLoopLineTestUrgDcDown is valid. Options: 1. valid(1) -the value of hwLoopLineTestUrgDcDown is valid 2. invalid(2) -the value o…
1.3.6.1.4.1.2011.6.21.1.1.1.2.1.143ColumnhwLoopLineTestUtrPosFlagread-onlycurrentIndicates whether the value of hwLoopLineTestUtrPos is valid. Options: 1. valid(1) -the value of hwLoopLineTestUtrPos is valid 2. invalid(2) -the value of hwLo…
1.3.6.1.4.1.2011.6.21.1.1.1.2.1.144ColumnhwLoopLineTestUtrNegFlagread-onlycurrentIndicates whether the value of hwLoopLineTestUtrNeg is valid. Options: 1. valid(1) -the value of hwLoopLineTestUtrNeg is valid 2. invalid(2) -the value of hwLo…
1.3.6.1.4.1.2011.6.21.1.1.1.2.1.145ColumnhwLoopLineTestItgDcUpFlagread-onlycurrentIndicates whether the value of hwLoopLineTestItgDcUp is valid. Options: 1. valid(1) -the value of hwLoopLineTestItgDcUp is valid 2. invalid(2) -the value of hw…
1.3.6.1.4.1.2011.6.21.1.1.1.2.1.146ColumnhwLoopLineTestItgDcDownFlagread-onlycurrentIndicates whether the value of hwLoopLineTestItgDcDown is valid. Options: 1. valid(1) -the value of hwLoopLineTestItgDcDown is valid 2. invalid(2) -the value o…
1.3.6.1.4.1.2011.6.21.1.1.1.2.1.147ColumnhwLoopLineTestIrgDcUpFlagread-onlycurrentIndicates whether the value of hwLoopLineTestIrgDcUp is valid. Options: 1. valid(1) -the value of hwLoopLineTestIrgDcUp is valid 2. invalid(2) -the value of hw…
1.3.6.1.4.1.2011.6.21.1.1.1.2.1.148ColumnhwLoopLineTestIrgDcDownFlagread-onlycurrentIndicates whether the value of hwLoopLineTestIrgDcDown is valid. Options: 1. valid(1) -the value of hwLoopLineTestIrgDcDown is valid 2. invalid(2) -the value o…
1.3.6.1.4.1.2011.6.21.1.1.1.2.1.149ColumnhwLoopLineTestItrPosFlagread-onlycurrentIndicates whether the value of hwLoopLineTestItrPos is valid. Options: 1. valid(1) -the value of hwLoopLineTestItrPos is valid 2. invalid(2) -the value of hwLo…
1.3.6.1.4.1.2011.6.21.1.1.1.2.1.150ColumnhwLoopLineTestItrNegFlagread-onlycurrentIndicates whether the value of hwLoopLineTestItrNeg is valid. Options: 1. valid(1) -the value of hwLoopLineTestItrNeg is valid 2. invalid(2) -the value of hwLo…
1.3.6.1.4.1.2011.6.21.1.1.1.2.1.151ColumnhwLoopLineTestRingerFlagread-onlycurrentIndicates whether the value of hwLoopLineTestRinger is valid. Options: 1. valid(1) -the value of hwLoopLineTestRinger is valid 2. invalid(2) -the value of hwLo…
1.3.6.1.4.1.2011.6.21.1.1.1.2.1.152ColumnhwLoopLineTestLRFlagread-onlycurrentIndicates whether the value of hwLoopLineTestLR is valid. Options: 1. valid(1) -the value of hwLoopLineTestLR is valid 2. invalid(2) -the value of hwLoopLineTe…
1.3.6.1.4.1.2011.6.21.1.1.1.2.1.153ColumnhwLoopLineTestDcCurrentread-createcurrentIndicates whether DcCurrent exists on the line under test. Options: 1. notest(1) -DcCurrent does not exist on the line under test 2. test(2) -DcCurrent exists …
1.3.6.1.4.1.2011.6.21.1.1.1.2.1.154ColumnhwLoopLineTestAcCurrentread-createcurrentIndicates whether AcCurrent exists on the line under test. Options: 1. notest(1) -AcCurrent does not exist on the line under test 2. test(2) -AcCurrent exists …
1.3.6.1.4.1.2011.6.21.1.1.1.2.1.155ColumnhwLoopLineTestConductanceread-createcurrentIndicates whether conductance exists on the line under test. Options: 1. notest(1) -Conductance does not exist on the line under test 2. test(2) -Conductance e…
1.3.6.1.4.1.2011.6.21.1.1.1.2.1.156ColumnhwLoopLineTestSusceptanceread-createcurrentIndicates whether susceptance exists on the line under test. Options: 1. notest(1) -Susceptance does not exist on the line under test 2. test(2) -Susceptance e…
1.3.6.1.4.1.2011.6.21.1.1.1.2.1.157ColumnhwLoopLineTestAcfrequencyAread-onlycurrentIndicates status of Acfrequency in line A. Options: 1. sixteenDotSix(1) -line A has ACFrequency 16.6 2. twentyFive(2) -line A has ACFrequency 25 3. fifty(3) -l…
1.3.6.1.4.1.2011.6.21.1.1.1.2.1.158ColumnhwLoopLineTestAcfrequencyBread-onlycurrentIndicates status of Acfrequency in line A. Options: 1. sixteenDotSix(1) -line A has ACFrequency 16.6 2. twentyFive(2) -line A has ACFrequency 25 3. fifty(3) -l…
1.3.6.1.4.1.2011.6.21.1.1.1.2.1.159ColumnhwLoopLineTestCapABHread-onlycurrentIndicates the A->B capacitance. Unit: nF
1.3.6.1.4.1.2011.6.21.1.1.1.2.1.160ColumnhwLoopLineTestCapABHFlagread-onlycurrentIndicates whether the value of hwLoopLineTestCapABH is valid. Options: 1. valid(1) -the value of hwLoopLineTestCapABH is valid 2. invalid(2) -the value of hwLo…
1.3.6.1.4.1.2011.6.21.1.1.1.2.1.161ColumnhwLoopLineTestGtrHread-onlycurrentIndicates the A->B conductance. Unit: nS
1.3.6.1.4.1.2011.6.21.1.1.1.2.1.162ColumnhwLoopLineTestGtrHFlagread-onlycurrentIndicates whether the value of hwLoopLineTestGtrH is valid. Options: 1. valid(1) -the value of hwLoopLineTestGtrH is valid 2. invalid(2) -the value of hwLoopLi…
1.3.6.1.4.1.2011.6.21.1.1.1.2.1.163ColumnhwLoopLineTestBtrHread-onlycurrentIndicates the A->B susceptance. Unit: nS
1.3.6.1.4.1.2011.6.21.1.1.1.2.1.164ColumnhwLoopLineTestBtrHFlagread-onlycurrentIndicates whether the value of hwLoopLineTestBtrH is valid. Options: 1. valid(1) -the value of hwLoopLineTestBtrH is valid 2. invalid(2) -the value of hwLoopLi…
1.3.6.1.4.1.2011.6.21.1.1.1.2.1.165ColumnhwLoopLineTestABDcCurrentread-onlycurrentIndicates the A->B Dc current. Unit: uA
1.3.6.1.4.1.2011.6.21.1.1.1.2.1.166ColumnhwLoopLineTestABDcCurrentFlagread-onlycurrentIndicates whether the value of hwLoopLineTestABDcCurrent is valid. Options: 1. valid(1) -the value of hwLoopLineTestABDcCurrent is valid 2. invalid(2) -the val…
1.3.6.1.4.1.2011.6.21.1.1.1.2.1.167ColumnhwLoopLineTestBADcCurrentread-onlycurrentIndicates the B->A Dc current. Unit: uA
1.3.6.1.4.1.2011.6.21.1.1.1.2.1.168ColumnhwLoopLineTestBADcCurrentFlagread-onlycurrentIndicates whether the value of hwLoopLineTestBADcCurrent is valid. Options: 1. valid(1) -the value of hwLoopLineTestBADcCurrent is valid 2. invalid(2) -the val…
1.3.6.1.4.1.2011.6.21.1.1.1.2.1.169ColumnhwLoopLineTestABAcCurrentread-onlycurrentIndicates the A->B Ac current. Unit: uArms
1.3.6.1.4.1.2011.6.21.1.1.1.2.1.170ColumnhwLoopLineTestABAcCurrentFlagread-onlycurrentIndicates whether the value of hwLoopLineTestABAcCurrent is valid. Options: 1. valid(1) -the value of hwLoopLineTestABAcCurrent is valid 2. invalid(2) -the val…
1.3.6.1.4.1.2011.6.21.1.1.1.2.1.171ColumnhwLoopLineTestBAAcCurrentread-onlycurrentIndicates the B->A Ac current. Unit: uArms
1.3.6.1.4.1.2011.6.21.1.1.1.2.1.172ColumnhwLoopLineTestBAAcCurrentFlagread-onlycurrentIndicates whether the value of hwLoopLineTestBAAcCurrent is valid. Options: 1. valid(1) -the value of hwLoopLineTestBAAcCurrent is valid 2. invalid(2) -the val…
1.3.6.1.4.1.2011.6.21.1.1.1.2.1.173ColumnhwLoopLineTestCSfrequencyForTestread-onlycurrentIndicates the frequency for test capacitance and conductance. Unit: Hz
1.3.6.1.4.1.2011.6.21.1.1.1.2.1.174ColumnhwLoopLineTestCSfrequencyForTestFlagread-onlycurrentIndicates whether the value of hwLoopLineTestCSfrequencyForTest is valid. Options: 1. valid(1) -the value of hwLoopLineTestCSfrequencyForTest is valid 2. inval…
1.3.6.1.4.1.2011.6.21.1.1.1.2.1.175ColumnhwLoopLineTestImpedanceForTestread-onlycurrentIndicates the resistance inputed in test abnormal voltage. Unit: ohm
1.3.6.1.4.1.2011.6.21.1.1.1.2.1.176ColumnhwLoopLineTestImpedanceForTestFlagread-onlycurrentIndicates whether the value of hwLoopLineTestImpedanceForTest is valid. Options: 1. valid(1) -the value of hwLoopLineTestImpedanceForTest is valid 2. invalid(2…
1.3.6.1.4.1.2011.6.21.1.1.1.2.1.177ColumnhwLoopLineTestMaxVForSignatureread-onlycurrentIndicates the maximum voltage for signature. Unit: mV
1.3.6.1.4.1.2011.6.21.1.1.1.2.1.178ColumnhwLoopLineTestMaxVForSignatureFlagread-onlycurrentIndicates whether the value of hwLoopLineTestMaxVForSignature is valid. Options: 1. valid(1) -the value of hwLoopLineTestMaxVForSignature is valid 2. invalid(2…
1.3.6.1.4.1.2011.6.21.1.1.1.2.1.179ColumnhwLoopLineTestAGMaxVForTestread-onlycurrentIndicates the A->ground max voltage in testing. Unit: mV
1.3.6.1.4.1.2011.6.21.1.1.1.2.1.180ColumnhwLoopLineTestAGMaxVForTestFlagread-onlycurrentIndicates whether the value of hwLoopLineTestAGMaxVForTest is valid. Options: 1. valid(1) -the value of hwLoopLineTestAGMaxVForTest is valid 2. invalid(2) -the…
1.3.6.1.4.1.2011.6.21.1.1.1.2.1.181ColumnhwLoopLineTestAGMinVForTestread-onlycurrentIndicates the A->ground min voltage in testing. Unit: mV
1.3.6.1.4.1.2011.6.21.1.1.1.2.1.182ColumnhwLoopLineTestAGMinVForTestFlagread-onlycurrentIndicates whether the value of hwLoopLineTestAGMinVForTest is valid. Options: 1. valid(1) -the value of hwLoopLineTestAGMinVForTest is valid 2. invalid(2) -the…
1.3.6.1.4.1.2011.6.21.1.1.1.2.1.183ColumnhwLoopLineTestBGMaxVForTestread-onlycurrentIndicates the B->ground max voltage in testing. Unit: mV
1.3.6.1.4.1.2011.6.21.1.1.1.2.1.184ColumnhwLoopLineTestBGMaxVForTestFlagread-onlycurrentIndicates whether the value of hwLoopLineTestBGMaxVForTest is valid. Options: 1. valid(1) -the value of hwLoopLineTestBGMaxVForTest is valid 2. invalid(2) -the…
1.3.6.1.4.1.2011.6.21.1.1.1.2.1.185ColumnhwLoopLineTestBGMinVForTestread-onlycurrentIndicates the B->ground min voltage in testing. Unit: mV
1.3.6.1.4.1.2011.6.21.1.1.1.2.1.186ColumnhwLoopLineTestBGMinVForTestFlagread-onlycurrentIndicates whether the value of hwLoopLineTestBGMinVForTest is valid. Options: 1. valid(1) -the value of hwLoopLineTestBGMinVForTest is valid 2. invalid(2) -the…
1.3.6.1.4.1.2011.6.21.1.1.1.2.1.187ColumnhwLoopLineTestABMaxVForTestread-onlycurrentIndicates the A->B max voltage in testing. Unit: mV
1.3.6.1.4.1.2011.6.21.1.1.1.2.1.188ColumnhwLoopLineTestABMaxVForTestFlagread-onlycurrentIndicates whether the value of hwLoopLineTestABMaxVForTest is valid. Options: 1. valid(1) -the value of hwLoopLineTestABMaxVForTest is valid 2. invalid(2) -the…
1.3.6.1.4.1.2011.6.21.1.1.1.2.1.189ColumnhwLoopLineTestABMinVForTestread-onlycurrentIndicates the A->ground min voltage in testing. Unit: mV
1.3.6.1.4.1.2011.6.21.1.1.1.2.1.190ColumnhwLoopLineTestABMinVForTestFlagread-onlycurrentIndicates whether the value of hwLoopLineTestABMinVForTest is valid. Options: 1. valid(1) -the value of hwLoopLineTestABMinVForTest is valid 2. invalid(2) -the…
1.3.6.1.4.1.2011.6.21.1.1.1.2.1.191ColumnhwLoopLineTestAGMaxCForTestread-onlycurrentIndicates the A->ground max current. Unit: uA
1.3.6.1.4.1.2011.6.21.1.1.1.2.1.192ColumnhwLoopLineTestAGMaxCForTestFlagread-onlycurrentIndicates whether the value of hwLoopLineTestAGMaxCForTest is valid. Options: 1. valid(1) -the value of hwLoopLineTestAGMaxCForTest is valid 2. invalid(2) -the…
1.3.6.1.4.1.2011.6.21.1.1.1.2.1.193ColumnhwLoopLineTestAGMinCForTestread-onlycurrentIndicates the A->ground min current. Unit: uA
1.3.6.1.4.1.2011.6.21.1.1.1.2.1.194ColumnhwLoopLineTestAGMinCForTestFlagread-onlycurrentIndicates whether the value of hwLoopLineTestAGMinCForTest is valid. Options: 1. valid(1) -the value of hwLoopLineTestAGMinCForTest is valid 2. invalid(2) -the…
1.3.6.1.4.1.2011.6.21.1.1.1.2.1.195ColumnhwLoopLineTestBGMaxCForTestread-onlycurrentIndicates the B->ground max current. Unit: uA
1.3.6.1.4.1.2011.6.21.1.1.1.2.1.196ColumnhwLoopLineTestBGMaxCForTestFlagread-onlycurrentIndicates whether the value of hwLoopLineTestBGMaxCForTest is valid. Options: 1. valid(1) -the value of hwLoopLineTestBGMaxCForTest is valid 2. invalid(2) -the…
1.3.6.1.4.1.2011.6.21.1.1.1.2.1.197ColumnhwLoopLineTestBGMinCForTestread-onlycurrentIndicates the B->ground min current. Unit: uA
1.3.6.1.4.1.2011.6.21.1.1.1.2.1.198ColumnhwLoopLineTestBGMinCForTestFlagread-onlycurrentIndicates whether the value of hwLoopLineTestBGMinCForTest is valid. Options: 1. valid(1) -the value of hwLoopLineTestBGMinCForTest is valid 2. invalid(2) -the…
1.3.6.1.4.1.2011.6.21.1.1.1.2.1.199ColumnhwLoopLineTestABMaxCForTestread-onlycurrentIndicates the A->B max current Unit: uA
1.3.6.1.4.1.2011.6.21.1.1.1.2.1.200ColumnhwLoopLineTestABMaxCForTestFlagread-onlycurrentIndicates whether the value of hwLoopLineTestABMaxCForTest is valid. Options: 1. valid(1) -the value of hwLoopLineTestABMaxCForTest is valid 2. invalid(2) -the…
1.3.6.1.4.1.2011.6.21.1.1.1.2.1.201ColumnhwLoopLineTestABMaxNegCForTestread-onlycurrentIndicates the A->ground min current Unit: uA
1.3.6.1.4.1.2011.6.21.1.1.1.2.1.202ColumnhwLoopLineTestABMaxNegCForTestFlagread-onlycurrentIndicates whether the value of hwLoopLineTestABMaxNegCForTest is valid. Options: 1. valid(1) -the value of hwLoopLineTestABMaxNegCForTest is valid 2. invalid(2…
1.3.6.1.4.1.2011.6.21.1.1.1.2.1.203ColumnhwLoopLineTestLineALengthread-onlycurrentIndicates length of line A Unit: m
1.3.6.1.4.1.2011.6.21.1.1.1.2.1.204ColumnhwLoopLineTestLineBLengthread-onlycurrentIndicates length of line B Unit: m
1.3.6.1.4.1.2011.6.21.1.1.1.2.1.205ColumnhwLoopLineTestTermimalConcusionread-onlycurrentIndicates Termimal Concusion Options: 1. noPhone(1) -the TermimalConcusion is not connect Phone 2. offHook(2) -the TermimalConcusion is connect phone and offho…
1.3.6.1.4.1.2011.6.21.1.1.1.2.1.206ColumnhwLoopLineTestMoreDataFlagread-onlycurrentIndicates is there more data Options: 1. more(1) -Indicates there is more data needs report,but needs a SNMP-GET oper. to get other data. 2. invalid(-1) -Indic…
1.3.6.1.4.1.2011.6.21.1.1.1.2.1.207ColumnhwLoopLineTestCtrLVread-onlycurrentAggregate tip-ring capacitance: CtrLV = Cco + Ctr + Cring, measured by means of low voltage ramps, such that it does NOT include the capacitance Csig whenever …
1.3.6.1.4.1.2011.6.21.1.1.1.2.1.208ColumnhwLoopLineTestCtrLVFlagread-onlycurrentIndicates whether the value of hwLoopLineTestCtrLV is valid. Options: 1. valid(1) -the value of hwLoopLineTestCtrLV is valid 2. invalid(2) -the value of hwLoop…
1.3.6.1.4.1.2011.6.21.1.1.1.2.1.209ColumnhwLoopLineTestCtrHVread-onlycurrentAggregate tip-ring capacitance: CtrHV = Cco + Ctr + Cring + Csig, measured by means of high voltage ramps. It includes the capacitance Csig of an ETSI Signatur…
1.3.6.1.4.1.2011.6.21.1.1.1.2.1.210ColumnhwLoopLineTestCtrHVFlagread-onlycurrentIndicates whether the value of hwLoopLineTestCtrHV is valid. Options: 1. valid(1) -the value of hwLoopLineTestCtrHV is valid 2. invalid(2) -the value of hwLoop…
1.3.6.1.4.1.2011.6.21.1.1.1.2.1.211ColumnhwLoopLineTestCtrAcread-onlycurrentAggregate tip-ring capacitance: CtrAc = Cco + Ctr + Cring, measured by means of a low amplitude AC signal (either 25 Hz or 275 Hz). It does NOT include Csig. U…
1.3.6.1.4.1.2011.6.21.1.1.1.2.1.212ColumnhwLoopLineTestCtrAcFlagread-onlycurrentIndicates whether the value of hwLoopLineTestCtrAc is valid. Options: 1. valid(1) -the value of hwLoopLineTestCtrAc is valid 2. invalid(2) -the value of hwLoop…
1.3.6.1.4.1.2011.6.21.1.1.1.2.1.213ColumnhwLoopLineTestRtgSerread-onlycurrentResistance in series with Ctg, measured at the selected AC frequency (either 25 Hz or 275 Hz) by means of a low amplitude AC signal. Unit: ohm
1.3.6.1.4.1.2011.6.21.1.1.1.2.1.214ColumnhwLoopLineTestRtgSerFlagread-onlycurrentIndicates whether the value of hwLoopLineTestRtgSer is valid. Options: 1. valid(1) -the value of hwLoopLineTestRtgSer is valid 2. invalid(2) -the value of hwLo…
1.3.6.1.4.1.2011.6.21.1.1.1.2.1.215ColumnhwLoopLineTestRrgSerread-onlycurrentResistance in series with Crg, measured at the selected AC frequency (either 25 Hz or 275 Hz) by means of a low amplitude AC signal. Unit: ohm
1.3.6.1.4.1.2011.6.21.1.1.1.2.1.216ColumnhwLoopLineTestRrgSerFlagread-onlycurrentIndicates whether the value of hwLoopLineTestRrgSer is valid. Options: 1. valid(1) -the value of hwLoopLineTestRrgSer is valid 2. invalid(2) -the value of hwLo…
1.3.6.1.4.1.2011.6.21.1.1.1.2.1.217ColumnhwLoopLineTestRtrSerread-onlycurrentResistance in series with Ctring, measured at the selected AC frequency (either 25 Hz or 275 Hz) by means of a low amplitude AC signal. Unit: ohm
1.3.6.1.4.1.2011.6.21.1.1.1.2.1.218ColumnhwLoopLineTestRtrSerFlagread-onlycurrentIndicates whether the value of hwLoopLineTestRtrSer is valid. Options: 1. valid(1) -the value of hwLoopLineTestRtrSer is valid 2. invalid(2) -the value of hwLo…
1.3.6.1.4.1.2011.6.21.1.1.1.2.1.219ColumnhwLoopLineTestUtgAcAdmitread-onlycurrentAmplitude of the AC signal (either 25 Hz or 275 Hz) applied to the tipground admittance Ytg = Gtg + i * Btg. Unit: V
1.3.6.1.4.1.2011.6.21.1.1.1.2.1.220ColumnhwLoopLineTestUtgAcAdmitFlagread-onlycurrentIndicates whether the value of hwLoopLineTestUtgAcAdmit is valid. Options: 1. valid(1) -the value of hwLoopLineTestUtgAcAdmit is valid 2. invalid(2) -the value…
1.3.6.1.4.1.2011.6.21.1.1.1.2.1.221ColumnhwLoopLineTestUrgAcAdmitread-onlycurrentAmplitude of the AC signal (either 25 Hz or 275 Hz) applied to the ringground admittance Yrg = Grg + i * Brg. Unit: V
1.3.6.1.4.1.2011.6.21.1.1.1.2.1.222ColumnhwLoopLineTestUrgAcAdmitFlagread-onlycurrentIndicates whether the value of hwLoopLineTestUrgAcAdmit is valid. Options: 1. valid(1) -the value of hwLoopLineTestUrgAcAdmit is valid 2. invalid(2) -the value…
1.3.6.1.4.1.2011.6.21.1.1.1.2.1.223ColumnhwLoopLineTestUtrAcAdmitread-onlycurrentAmplitude of the AC signal (either 25 Hz or 275 Hz) applied to the tip-ring admittance Ytr = Gtr + i * Btr. Unit: V
1.3.6.1.4.1.2011.6.21.1.1.1.2.1.224ColumnhwLoopLineTestUtrAcAdmitFlagread-onlycurrentIndicates whether the value of hwLoopLineTestUtrAcAdmit is valid. Options: 1. valid(1) -the value of hwLoopLineTestUtrAcAdmit is valid 2. invalid(2) -the value…
1.3.6.1.4.1.2011.6.21.1.1.1.2.1.225ColumnhwLoopLineTestCapterminalread-onlycurrentA capacitive termination of the access line shall be identified by the capacitance measurement and the associated evaluation. The following average value for t…
1.3.6.1.4.1.2011.6.21.1.1.1.2.1.226ColumnhwLoopLineTestCapterminalFlagread-onlycurrentIndicates whether the value of hwLoopLineTestCapterminal is valid. Options: 1. valid(1) -the value of hwLoopLineTestCapterminal is valid 2. invalid(2) -the val…
1.3.6.1.4.1.2011.6.21.1.1.1.3TablehwMeterTestOprTablenot-accessiblecurrentOperation table of the meter test. It implements the meter test function in the system. The test board provides the interface connected to the external test me…
1.3.6.1.4.1.2011.6.21.1.1.1.3.1RowhwMeterTestOprEntrynot-accessiblecurrentOperation table of the meter test. It implements the meter test function in the system. The test board provides the interface connected to the external test me…
1.3.6.1.4.1.2011.6.21.1.1.1.3.1.1ColumnhwMeterTestOprTyperead-createcurrentOperation type. Options: 1. stop(1) -operation type is stop 2. start(2) -operation type is start
1.3.6.1.4.1.2011.6.21.1.1.1.3.1.2ColumnhwMeterTestItemread-createcurrentTest items. Options: 1. inline(1) -in test 2. outline(2) -out test
1.3.6.1.4.1.2011.6.21.1.1.1.3.1.3ColumnhwMeterTestStatusread-onlycurrentTest status. Options: 1. success(1) -no test on busy 2. fail(2) -remedy test on busy 3. portbusy(3) -forced test on busy 4. outoftime(4) -test out of time 5. t…
1.3.6.1.4.1.2011.6.21.1.1.1.3.1.4ColumnhwMeterTestBusyFlagread-writecurrentMeter test busy flag. Options: 1. busyNoTest(1) -no test on busy 2. busyTest(2) -test on busy 3. busystrenTest(3) -forced test on busy
1.3.6.1.4.1.2011.6.21.1.1.1.4TablehwTestBoardDiagnoseTestOprTablenot-accessiblecurrentOperation table of the self-test on the test board. It implements the self-test on the test board in the system. The self-test checks whether the test board ca…
1.3.6.1.4.1.2011.6.21.1.1.1.4.1RowhwTestBoardDiagnoseTestOprEntrynot-accessiblecurrentOperation table of the self-test on the test board. It implements the self-test on the test board in the system. The self-test checks whether the test board ca…
1.3.6.1.4.1.2011.6.21.1.1.1.4.1.1ColumnhwTestBoardDiagnoseTestOprTyperead-createcurrentOperation type. Options: 1. start(2) -operation type is start
1.3.6.1.4.1.2011.6.21.1.1.1.4.1.2ColumnhwTestBoardDiagnoseTestResultread-onlycurrentSelf-diagnosis result. Options: 1. selfTestOver(1) -self-diagnosis successful 2. selfTestFail(2) -self-diagnosis failure 3. testingAbnormal(3) -test abnormal
1.3.6.1.4.1.2011.6.21.1.1.1.4.1.3ColumnhwTestBoardDiagnoseTestRAMread-onlycurrentSystem RAMRAM. Options: 1. normal(1) -normal 2. abnormal(2) -abnormal
1.3.6.1.4.1.2011.6.21.1.1.1.4.1.4ColumnhwTestBoardDiagnoseTestVoltageread-onlycurrentVoltage. Options: 1. normal(1) -normal 2. abnormal(2) -abnormal
1.3.6.1.4.1.2011.6.21.1.1.1.4.1.5ColumnhwTestBoardDiagnoseTestResistanceread-onlycurrentResistance. Options: 1. normal(1) -normal 2. abnormal(2) -abnormal
1.3.6.1.4.1.2011.6.21.1.1.1.4.1.6ColumnhwTestBoardDiagnoseTestSignalread-onlycurrentSignal circuit. Options: 1. normal(1) -normal 2. abnormal(2) -abnormal
1.3.6.1.4.1.2011.6.21.1.1.1.4.1.7ColumnhwTestBoardDiagnoseTestDTMFread-onlycurrentDTMF. Options: 1. normal(1) -normal 2. abnormal(2) -abnormal
1.3.6.1.4.1.2011.6.21.1.1.1.4.1.8ColumnhwTestBoardDiagnoseTestRingread-onlycurrentRinging. Options: 1. normal(1) -normal 2. abnormal(2) -abnormal
1.3.6.1.4.1.2011.6.21.1.1.1.4.1.9ColumnhwTestBoardDiagnoseTestOnOffHookread-onlycurrentOn/off hook. Options: 1. normal(1) -normal 2. abnormal(2) -abnormal
1.3.6.1.4.1.2011.6.21.1.1.1.4.1.10ColumnhwTestBoardDiagnoseTestPoleread-onlycurrentPolarity reversal. Options: 1. normal(1) -normal 2. abnormal(2) -abnormal
1.3.6.1.4.1.2011.6.21.1.1.1.4.1.11ColumnhwTestBoardDiagnoseTestISDNUread-onlycurrentISDN U port. Options: 1. normal(1) -normal 2. abnormal(2) -abnormal
1.3.6.1.4.1.2011.6.21.1.1.1.4.1.12ColumnhwTestBoardDiagnoseTestBitErrCoderead-onlycurrentError code test. Options: 1. normal(1) -normal 2. abnormal(2) -abnormal
1.3.6.1.4.1.2011.6.21.1.1.1.4.1.13ColumnhwTestBoardDiagnoseTestCapacitanceread-onlycurrentCapacitance. Options: 1. normal(1) -normal 2. abnormal(2) -abnormal
1.3.6.1.4.1.2011.6.21.1.1.1.5TablehwTestBoardStatusQueryOprTablenot-accessiblecurrentOperation table for querying the status of the test board. It implements the function of querying the status of the test board in the system. You can query the…
1.3.6.1.4.1.2011.6.21.1.1.1.5.1RowhwTestBoardStatusQueryOprEntrynot-accessiblecurrentOperation table for querying the status of the test board. It implements the function of querying the status of the test board in the system. You can query the…
1.3.6.1.4.1.2011.6.21.1.1.1.5.1.1ColumnhwTestBoardStatusQueryOprTyperead-createcurrentOperation type. Options: 1. beginQuery(2) -start
1.3.6.1.4.1.2011.6.21.1.1.1.5.1.2ColumnhwTestBoardStatusQueryResultread-onlycurrentQuery status. Options: 1. querySuccess(1) -query status successful 2. queryFail(2) -query status failure
1.3.6.1.4.1.2011.6.21.1.1.1.5.1.3ColumnhwTestBoardStatusQueryVersionread-onlycurrentVersion.
1.3.6.1.4.1.2011.6.21.1.1.1.5.1.4ColumnhwTestBoardStatusQueryTestItemread-onlycurrentTest item. Options: 1. testIdle(1) -idle 2. pstnUserInLineTest(2) -pstn inline test 3. userLineTest(3) -loop line test 4. phoneTest(4) -telephone test 5. manTe…
1.3.6.1.4.1.2011.6.21.1.1.1.5.1.5ColumnhwTestBoardStatusTestedBoardIfIndexread-onlycurrentIndex of the tested port.
1.3.6.1.4.1.2011.6.21.1.1.1.6TablehwSearchingToneOprTablenot-accessiblecurrentThis table is used for enabling the searching tone test by setting the searching tone test voltage level, test frequency, and test duration. The searching tone…
1.3.6.1.4.1.2011.6.21.1.1.1.6.1RowhwSearchingToneOprEntrynot-accessiblecurrentThis table is used for enabling the searching tone test by setting the searching tone test voltage level, test frequency, and test duration. The searching tone…
1.3.6.1.4.1.2011.6.21.1.1.1.6.1.1ColumnhwSearchingToneOprTyperead-writecurrentSearching tone test-operation type. Options: 1. stop(1) -stop a searching tone test 2. start(2) -start a searching tone test 3. invalid(-1) -invalid value
1.3.6.1.4.1.2011.6.21.1.1.1.6.1.2ColumnhwSearchingToneLevelread-writecurrentIndicates the test voltage level of a searching tone test. Options: 1. -1 -Invalid value 2. 80..500 -(XDSL Range: 80-126 MXU voice Range: 80-500) Default: 120 …
1.3.6.1.4.1.2011.6.21.1.1.1.6.1.3ColumnhwSearchingToneFrequencyread-writecurrentIndicates the test frequency of a searching tone test. Default: 800 Unit: Hz
1.3.6.1.4.1.2011.6.21.1.1.1.6.1.4ColumnhwSearchingToneDurationTimeread-writecurrentIndicates the test duration of a searching tone test. Default: 9000 Unit: 0.1s
1.3.6.1.4.1.2011.6.21.1.1.1.6.1.5ColumnhwSearchingToneRemainingTimeread-onlycurrentIndicates the test remaining time of a searching tone test. Unit: 0.1s
1.3.6.1.4.1.2011.6.21.1.1.1.6.1.6ColumnhwSearchingToneBusyProcFlagread-writecurrentSearching tone test-busy flag. Options: 1. cancel(1) -when port is busy do not start a searching tone test 2. force(2) -when port is busy force to start a sear…
1.3.6.1.4.1.2011.6.21.1.1.1.7TablehwLoopLineTestCalibrationTablenot-accessiblecurrentThis table provides the test calibration data of a line. Before delivery, each port is performed with a test in which no user is connected to the port and the …
1.3.6.1.4.1.2011.6.21.1.1.1.7.1RowhwLoopLineTestCalibrationEntrynot-accessiblecurrentThis table provides the test calibration data of a line. Before delivery, each port is performed with a test in which no user is connected to the port and the …
1.3.6.1.4.1.2011.6.21.1.1.1.7.1.1ColumnhwLoopLineTestAGCalibrationread-onlycurrentIndicates the test calibration data of A->Ground capacitance. Unit: nF
1.3.6.1.4.1.2011.6.21.1.1.1.7.1.2ColumnhwLoopLineTestBGCalibrationread-onlycurrentIndicates the test calibration data of B->Ground capacitance. Unit: nF
1.3.6.1.4.1.2011.6.21.1.1.1.7.1.3ColumnhwLoopLineTestABCalibrationread-onlycurrentIndicates the test calibration data of A->B capacitance. Unit: nF
1.3.6.1.4.1.2011.6.21.1.1.1.8TablehwLoopLineTestMeltVerTablenot-accessiblecurrentThis table provides the information about the MELT chip on the board, including the vendor, hardware version, and software version. The indexes of this table a…
1.3.6.1.4.1.2011.6.21.1.1.1.8.1RowhwLoopLineTestMeltVerEntrynot-accessiblecurrentThis table provides the information about the MELT chip on the board, including the vendor, hardware version, and software version. The indexes of this entry a…
1.3.6.1.4.1.2011.6.21.1.1.1.8.1.1ColumnhwLoopLineTestMeltFactoryread-onlycurrentMELT chipset manufacturer information Maximum length: 32 Octets
1.3.6.1.4.1.2011.6.21.1.1.1.8.1.2ColumnhwLoopLineTestMeltChipread-onlycurrentMELT chipset manufacturer hardware information Maximum length: 128 Octets
1.3.6.1.4.1.2011.6.21.1.1.1.8.1.3ColumnhwLoopLineTestMeltFirmwareVerread-onlycurrentMELT chipset manufacturer version information Maximum length: 16 Octets
1.3.6.1.4.1.2011.6.21.1.1.1.9NodehwLoopLineTestSysConfigPara
1.3.6.1.4.1.2011.6.21.1.1.1.9.1ScalarhwLoopLineTestSysConfigConvertABread-writecurrentIndicates the polarity of A wire and B wire. Options: 1. normal(1) -default polarity of A wire and B wire 2. reverse(2) -reverse polarity of A wire and B wire …
1.3.6.1.4.1.2011.6.21.1.1.1.9.2ScalarhwLoopLineTestSysConfigCableFactorread-writecurrentThe cable-factor used to detect significant terminal device capacitance. The cable-factor ranges from 1 to 1000 units of 0.001 (Physical values are 0.001 to 1,…
1.3.6.1.4.1.2011.6.21.1.1.1.9.3ScalarhwLoopLineTestSysConfigSigCapUpperLimitread-writecurrentThe three parameters(capacitance's upper-limit value, lower-limit value and resistance value) are used to determine the signature's existence. The capacitance …
1.3.6.1.4.1.2011.6.21.1.1.1.9.4ScalarhwLoopLineTestSysConfigSigCapLowerLimitread-writecurrentThe three parameters(capacitance's upper-limit value, lower-limit value and resistance value) are used to determine the signature's existence. The capacitance …
1.3.6.1.4.1.2011.6.21.1.1.1.9.5ScalarhwLoopLineTestSysConfigSigResistanceread-writecurrentThe three parameters(capacitance's upper-limit value, lower-limit value and resistance value) are used to determine the signature's existence. The resistance r…
1.3.6.1.4.1.2011.6.21.1.1.1.10TablehwONTPotsTestOprTablenot-accessiblecurrentThis table is used for enabling the POTS port line test of the ONT by setting the test item, test frequency, and test threshold. This test helps operators loca…
1.3.6.1.4.1.2011.6.21.1.1.1.10.1RowhwONTPotsTestOprEntrynot-accessiblecurrentThis table is used for enabling the POTS port line test of the ONT by setting the test item, test frequency, and test threshold. This test helps operators loca…
1.3.6.1.4.1.2011.6.21.1.1.1.10.1.1ColumnhwONTPotsTestONTIndexaccessible-for-notifycurrentONT ID.
1.3.6.1.4.1.2011.6.21.1.1.1.10.1.2ColumnhwONTPotsTestONTPstnPortIndexaccessible-for-notifycurrentONT port ID.
1.3.6.1.4.1.2011.6.21.1.1.1.10.1.3ColumnhwONTPotsTestOprTyperead-createcurrentPOTS port line Test-operation type. Options: 1. stop(1) -stop a POTS port line test 2. start(2) -start a POTS port line test 3. invalid(-1) -invalid value
1.3.6.1.4.1.2011.6.21.1.1.1.10.1.4ColumnhwONTPotsTestItemread-createcurrentPOTS port line test item. Options: 1. allMLTTests(1) -outdoor connection test 2. hazardousPotential(2) -hazardous potential test 3. foreignEMF(3) -foreign elec…
1.3.6.1.4.1.2011.6.21.1.1.1.10.1.5ColumnhwONTPotsTestBusyProcFlagread-createcurrentTest mode when a line is busy. Options: 1. cancel(1) -deny a test if a line is busy 2. force(2) -forced mode
1.3.6.1.4.1.2011.6.21.1.1.1.10.1.6ColumnhwONTPotsTestT1Thresholdread-createcurrentSlow dial tone threshold. Options: 1. 0 -Invalid value. It indicates that an ONT will use its default value 2. 100..6000 -Valid value range
1.3.6.1.4.1.2011.6.21.1.1.1.10.1.7ColumnhwONTPotsTestT2Thresholdread-createcurrentNo dial tone threshold. Options: 1. 0 -Invalid value. It indicates that an ONT will use its default value 2. 1000..10000 -Valid value range
1.3.6.1.4.1.2011.6.21.1.1.1.10.1.8ColumnhwONTPotsTestT3Thresholdread-createcurrentSlow break dial tone threshold. Options: 1. 0 -Invalid value. It indicates that an ONT will use its default value 2. 100..3000 -Valid value range
1.3.6.1.4.1.2011.6.21.1.1.1.10.1.9ColumnhwONTPotsTestT4Thresholdread-createcurrentNo break dial tone threshold. Options: 1. 0 -Invalid value. It indicates that an ONT will use its default value 2. 1000..3000 -Valid value range
1.3.6.1.4.1.2011.6.21.1.1.1.10.1.10ColumnhwONTPotsTestDtmfDigitread-createcurrentDTMF test number. Options: 1. zero(1) -the test number is 0 2. one(2) -the test number is 1 3. two(3) -the test number is 2 4. three(4) -the test number is 3 5…
1.3.6.1.4.1.2011.6.21.1.1.1.10.1.11ColumnhwONTPotsTestDialTyperead-createcurrentThe dialling type of dialling tone test. Options: 1. dtmf(1) -dtmf type 2. pulse(2) -pulse type
1.3.6.1.4.1.2011.6.21.1.1.1.10.1.12ColumnhwONTPotsTestDialToneFreq1read-createcurrentThe frequency1 in the dialling tone test. 0 -unused Unit: Hz
1.3.6.1.4.1.2011.6.21.1.1.1.10.1.13ColumnhwONTPotsTestDialToneFreq2read-createcurrentThe frequency2 in the dialling tone test. 0 -unused Unit: Hz
1.3.6.1.4.1.2011.6.21.1.1.1.10.1.14ColumnhwONTPotsTestDialToneFreq3read-createcurrentThe frequency3 in the dialling tone test. 0 -unused Unit: Hz
1.3.6.1.4.1.2011.6.21.1.1.1.10.1.15ColumnhwONTPotsTestDialToneEnergyThresholdread-createcurrentThe value of energy threshold in the dialling tone test. Valid value: 1. 0x00: unspecified 2. 0x01-0xFD: -0.1 dBm0 to -25.3 dBm0 Unit: 0.1 dBm0
1.3.6.1.4.1.2011.6.21.1.1.1.10.1.16ColumnhwONTPotsTestIdleChannelEnergyThresholdread-createcurrentThe value of energy threshold in the dialling tone test when the line is in the idle state. Valid value: 1. 0x00: unspecified 2. 0x01-0x5A: -1 dBm0 to -90 dBm0…
1.3.6.1.4.1.2011.6.21.1.1.1.10.1.17ColumnhwONTPotsTestDCHazardousVoltThresholdread-createcurrentThe value of DC voltage threshold in the hazardous potential test. 0x00 -unspecified Unit: volt
1.3.6.1.4.1.2011.6.21.1.1.1.10.1.18ColumnhwONTPotsTestACHazardousVoltThresholdread-createcurrentThe value of AC voltage threshold in the hazardous potential test. 0x00 -unspecified Unit: volt.
1.3.6.1.4.1.2011.6.21.1.1.1.10.1.19ColumnhwONTPotsTestDCForeignVoltThresholdread-createcurrentThe value of DC voltage threshold in the foreign volt test. 0x00 -unspecified Unit: volt
1.3.6.1.4.1.2011.6.21.1.1.1.10.1.20ColumnhwONTPotsTestACForeignVoltThresholdread-createcurrentThe value of AC voltage threshold in the foreign volt test. 0x00 -unspecified Unit: volt
1.3.6.1.4.1.2011.6.21.1.1.1.10.1.21ColumnhwONTPotsTestAGBGResistanceThresholdread-createcurrentThe resistance (tip to ground, ring to ground) threshold in the resistive faults test. 0x00 -unspecified Unit: kilohm
1.3.6.1.4.1.2011.6.21.1.1.1.10.1.22ColumnhwONTPotsTestABResistanceThresholdread-createcurrentThe resistance (tip to ring) threshold in the resistive faults test. 0x00 -unspecified Unit: kilohm
1.3.6.1.4.1.2011.6.21.1.1.1.10.1.23ColumnhwONTPotsTestRingerEquivMinThresholdread-createcurrentRinger equivalence minimum threshold. 0x00 -unspecified Unit: 0.01 REN
1.3.6.1.4.1.2011.6.21.1.1.1.10.1.24ColumnhwONTPotsTestRingerEquivMaxThresholdread-createcurrentRinger equivalence maximum threshold. 0x00 -unspecified Unit: 0.01 REN
1.3.6.1.4.1.2011.6.21.1.1.1.10.1.25ColumnhwONTPotsTestMLTResultread-onlycurrentMLT qualitative test result. Options: 1. failed(1) -a test fails 2. passOrNotRun(2) -a test passes or the test does not run
1.3.6.1.4.1.2011.6.21.1.1.1.10.1.26ColumnhwONTPotsTestHazardousVoltResultread-onlycurrentHazardous volt test result. Options: 1. failed(1) -a test fails 2. passOrNotRun(2) -a test passes or the test does not run
1.3.6.1.4.1.2011.6.21.1.1.1.10.1.27ColumnhwONTPotsTestEMFResultread-onlycurrentEMF test result. Options: 1. failed(1) -a test fails 2. passOrNotRun(2) -a test passes or the test does not run
1.3.6.1.4.1.2011.6.21.1.1.1.10.1.28ColumnhwONTPotsTestResistacneResultread-onlycurrentResistacne test result. Options: 1. failed(1) -a test fails 2. passOrNotRun(2) -a test passes or the test does not run
1.3.6.1.4.1.2011.6.21.1.1.1.10.1.29ColumnhwONTPotsTestOffHookResultread-onlycurrentThe off-hook test result. Options: 1. failed(1) -a test fails 2. passOrNotRun(2) -a test passes or the test does not run
1.3.6.1.4.1.2011.6.21.1.1.1.10.1.30ColumnhwONTPotsTestRingerResultread-onlycurrentRinger test result. Options: 1. failed(1) -a test fails 2. passOrNotRun(2) -a test passes or the test does not run
1.3.6.1.4.1.2011.6.21.1.1.1.10.1.31ColumnhwONTPotsTestNT1DCSignalResultread-onlycurrentNT1 DC Signal test result. Options: 1. failed(1) -a test fails 2. passOrNotRun(2) -a test passes or the test does not run
1.3.6.1.4.1.2011.6.21.1.1.1.10.1.32ColumnhwONTPotsTestSelfTestResultread-onlycurrentSelf test result. Options: 1. failed(1) -a test fails 2. passOrNotRun(2) -a test passes or the test does not run 3. notCompleted(3) -a test is not complete yet
1.3.6.1.4.1.2011.6.21.1.1.1.10.1.33ColumnhwONTPotsTestDrawDialToneResultread-onlycurrentDraw dialling tone test result. Options: 1. notRun(1) -a test does not run 2. couldNotDraw1(3) -a test fails to draw 3. couldNotDraw2(4) -a test fails to draw …
1.3.6.1.4.1.2011.6.21.1.1.1.10.1.34ColumnhwONTPotsTestBreakDialToneResultread-onlycurrentThe break dialling tone test result. Options: 1. notRun(1) -a test does not run 2. couldNotDraw1(3) -a test fails to draw 3. couldNotDraw2(4) -a test fails to …
1.3.6.1.4.1.2011.6.21.1.1.1.10.1.35ColumnhwONTPotsTestQuietEnergyResultread-onlycurrentThe quiet energy test result. Options: 1. notRun(1) -a test does not run 2. failMeasurementNotReported(3) -a test fails the measurement is not reported 3. fail…
1.3.6.1.4.1.2011.6.21.1.1.1.10.1.36ColumnhwONTPotsTestDialToneEnergyResultread-onlycurrentThe dialling tone energy test result. Options: 1. notRun(1) -a test does not run 2. failMeasurementNotReported(3) -a test fails the measurement is not reported…
1.3.6.1.4.1.2011.6.21.1.1.1.10.1.37ColumnhwONTPotsTestLoopDCAGVoltResultread-onlycurrentThe DC A-G (tip to ground) volt loop test result. Options: 1. notRun(1) -a test does not run 2. failMeasurementNotReported(3) -a test fails the measurement is …
1.3.6.1.4.1.2011.6.21.1.1.1.10.1.38ColumnhwONTPotsTestLoopDCBGVoltResultread-onlycurrentThe DC B-G (ring to ground) volt loop test result. Options: 1. notRun(1) -a test does not run. 2. failMeasurementNotReported(3) -a test fails the measurement i…
1.3.6.1.4.1.2011.6.21.1.1.1.10.1.39ColumnhwONTPotsTestLoopACAGVoltResultread-onlycurrentThe AC A-G (tip to ground) volt loop test result. Options: 1. notRun(1) -a test does not run 2. failMeasurementNotReported(3) -a test fails the measurement is …
1.3.6.1.4.1.2011.6.21.1.1.1.10.1.40ColumnhwONTPotsTestLoopACBGVoltResultread-onlycurrentThe AC B-G (ring to ground) volt loop test result. Options: 1. notRun(1) -a test does not run 2. failMeasurementNotReported(3) -a test fails the measurement is…
1.3.6.1.4.1.2011.6.21.1.1.1.10.1.41ColumnhwONTPotsTestLoopResistanceAGResultread-onlycurrentThe A-G (ring to ground) resistance loop test result. Options: 1. notRun(1) -a test does not run 2. failMeasurementNotReported(3) -a test fails the measurement…
1.3.6.1.4.1.2011.6.21.1.1.1.10.1.42ColumnhwONTPotsTestLoopResistanceBGResultread-onlycurrentThe B-G (ring to ground) resistance loop test result. Options: 1. notRun(1) -a test does not run 2. failMeasurementNotReported(3) -a test fails the measurement…
1.3.6.1.4.1.2011.6.21.1.1.1.10.1.43ColumnhwONTPotsTestLoopResistanceABResultread-onlycurrentThe A-B (tip to ring) resistance loop test result. Options: 1. notRun(1) -a test does not run 2. failMeasurementNotReported(3) -a test fails the measurement is…
1.3.6.1.4.1.2011.6.21.1.1.1.10.1.44ColumnhwONTPotsTestLoopRingerLoadTestResultread-onlycurrentThe ringer load Loop test result. Options: 1. notRun(1) -a test does not run 2. failMeasurementNotReported(3) -a test fails the measurement is not reported 3. …
1.3.6.1.4.1.2011.6.21.1.1.1.10.1.45ColumnhwONTPotsTestDrawDialToneTimeValueread-onlycurrentThe draw dial tone test result. Valid only if value of hwONTPotsTestDrawDialToneResult is couldNotDraw2(4), slowDraw2(6) or pass2(8). Unit: 100ms. Step: 100ms.
1.3.6.1.4.1.2011.6.21.1.1.1.10.1.46ColumnhwONTPotsTestBreakDialToneTimeValueread-onlycurrentThe break dial tone test result. Valid only if value of hwONTPotsTestBreakDialToneResult is couldNotDraw2(4), slowDraw2(6) or pass2(8). Unit: 100ms. Step: 100 …
1.3.6.1.4.1.2011.6.21.1.1.1.10.1.47ColumnhwONTPotsTestQuietEnergyValueread-onlycurrentThe quiet energy test result. Valid only if value of hwONTPotsTestQuietEnergyResult is failMeasurementReported(4) or passMeasurementReported(8). Values: 0-90 :…
1.3.6.1.4.1.2011.6.21.1.1.1.10.1.48ColumnhwONTPotsTestDialToneEnergyValueread-onlycurrentThe dial energy test result. Valid only if value of hwONTPotsTestDialToneEnergyResult is failMeasurementReported(4) or passMeasurementReported(8). Values: 0-25…
1.3.6.1.4.1.2011.6.21.1.1.1.10.1.49ColumnhwONTPotsTestLoopDCAGVoltValueread-onlycurrentThe DC A-G(Tip-ground) volt Loop test result or Subscriber line test result. 2s complement, resolution 1V. Valid only if value of hwONTPotsTestLoopDCAGVoltResu…
1.3.6.1.4.1.2011.6.21.1.1.1.10.1.50ColumnhwONTPotsTestLoopDCBGVoltValueread-onlycurrentThe DC B-G(Ring-ground) volt Loop test result or Subscriber line test result. 2s complement, resolution 1V. Valid only if value of hwONTPotsTestLoopDCBGVoltRes…
1.3.6.1.4.1.2011.6.21.1.1.1.10.1.51ColumnhwONTPotsTestLoopACAGVoltValueread-onlycurrentThe AC A-G(Tip-ground) volt Loop test result or Subscriber line test result. Valid only if value of hwONTPotsTestLoopACAGVoltResult is failMeasurementReported(…
1.3.6.1.4.1.2011.6.21.1.1.1.10.1.52ColumnhwONTPotsTestLoopACBGVoltValueread-onlycurrentThe AC B-G(Ring-ground) volt Loop test result or Subscriber line test result. Valid only if value of hwONTPotsTestLoopACBGVoltResult is failMeasurementReported…
1.3.6.1.4.1.2011.6.21.1.1.1.10.1.53ColumnhwONTPotsTestLoopResistanceAGValueread-onlycurrentThe A-G (tip to ground) resistance loop test result or Subscriber line test result. Unit: kilohm. Infinite resistance: 65535. Valid only if value of hwONTPotsT…
1.3.6.1.4.1.2011.6.21.1.1.1.10.1.54ColumnhwONTPotsTestLoopResistanceBGValueread-onlycurrentThe B-G (ring to ground) resistance loop test result or Subscriber line test result. Unit: kilohm. Infinite resistance: 65535. Valid only if value of hwONTPots…
1.3.6.1.4.1.2011.6.21.1.1.1.10.1.55ColumnhwONTPotsTestLoopResistanceABValueread-onlycurrentThe A-B (tip to ring) resistance loop test result or Subscriber line test result. Unit: kilohm. Infinite resistance: 65535. Valid only if value of hwONTPotsTes…
1.3.6.1.4.1.2011.6.21.1.1.1.10.1.56ColumnhwONTPotsTestLoopRingerLoadTestValueread-onlycurrentThe ringer load test result. Valid only if value of hwONTPotsTestLoopRingerLoadTestResult is failMeasurementReported(4) or passMeasurementReported(8). Unit: 0.…
1.3.6.1.4.1.2011.6.21.1.1.1.10.1.57ColumnhwONTPotsTestSubscriberLineTestResultread-onlycurrentThe subscriber line test result. Options: 1. normal(1) -subscriber line test normal 2. acCurrentAbnormal(12) -AC current abnormal 3. dcCurrentAbnormal(13) -DC …
1.3.6.1.4.1.2011.6.21.1.1.1.10.1.58ColumnhwONTPotsTestLoopDCABVoltValueread-onlycurrentThe DC A-B (tip-Ring) volt result of subscriber line test. Unit: volt.
1.3.6.1.4.1.2011.6.21.1.1.1.10.1.59ColumnhwONTPotsTestLoopACABVoltValueread-onlycurrentThe AC A-B (Tip-Ring) volt result of subscriber line test. Unit: volt.
1.3.6.1.4.1.2011.6.21.1.1.1.10.1.60ColumnhwONTPotsTestLoopAGCapacitanceValueread-onlycurrentThe A->G (Tip-Ground) capacitance result of subscriber line test. Unit: nF
1.3.6.1.4.1.2011.6.21.1.1.1.10.1.61ColumnhwONTPotsTestLoopBGCapacitanceValueread-onlycurrentThe B->G (Ring-Ground) capacitance result of subscriber line test. Unit: nF
1.3.6.1.4.1.2011.6.21.1.1.1.10.1.62ColumnhwONTPotsTestLoopABCapacitanceValueread-onlycurrentThe A->B (Tip-Ring) capacitance result of subscriber line test. Unit: nF
1.3.6.1.4.1.2011.6.21.1.1.1.10.1.63ColumnhwONTPotsTestLoopDCAGVoltCompensativeValueread-onlycurrentThe DC A->G (Tip-Ground) volt compensative result of subscriber line test. Unit: mV
1.3.6.1.4.1.2011.6.21.1.1.1.10.1.64ColumnhwONTPotsTestLoopDCBGVoltCompensativeValueread-onlycurrentThe DC B->G (Ring-Ground) volt compensative result of subscriber line test. Unit: mV
1.3.6.1.4.1.2011.6.21.1.1.1.10.1.65ColumnhwONTPotsTestLoopDCABVoltCompensativeValueread-onlycurrentThe DC A->B (Tip-Ring) volt compensative result of subscriber line test. Unit: mV
1.3.6.1.4.1.2011.6.21.1.1.1.10.1.66ColumnhwONTPotsTestLoopACAGVoltCompensativeValueread-onlycurrentThe AC A->G (Tip-Ground) volt compensative result of subscriber line test. Unit: mVrms
1.3.6.1.4.1.2011.6.21.1.1.1.10.1.67ColumnhwONTPotsTestLoopACBGVoltCompensativeValueread-onlycurrentThe AC B->G (Ring-Ground) volt compensative result of subscriber line test. Unit: mVrms
1.3.6.1.4.1.2011.6.21.1.1.1.10.1.68ColumnhwONTPotsTestLoopACABVoltCompensativeValueread-onlycurrentThe AC A->B (Tip-Ring) volt compensative result of subscriber line test. Unit: mVrms
1.3.6.1.4.1.2011.6.21.1.1.1.10.1.69ColumnhwONTPotsTestLoopResistanceAGCompensativeValueread-onlycurrentThe A-G (tip to ground) resistance compensative result of subscriber line test. Unit: ohm
1.3.6.1.4.1.2011.6.21.1.1.1.10.1.70ColumnhwONTPotsTestLoopResistanceBGCompensativeValueread-onlycurrentThe B-G (Ring to ground) resistance compensative result of subscriber line test. Unit: ohm
1.3.6.1.4.1.2011.6.21.1.1.1.10.1.71ColumnhwONTPotsTestLoopResistanceABCompensativeValueread-onlycurrentThe A-B (tip to Ring) resistance compensative result of subscriber line test. Unit: ohm
1.3.6.1.4.1.2011.6.21.1.1.1.11TablehwPortTestingListOprTablenot-accessiblecurrentThis table is used to query the ports under a test by board. The indexes of this table are hwFrameIndex and hwSlotIndex.
1.3.6.1.4.1.2011.6.21.1.1.1.11.1RowhwPortTestingListOprEntrynot-accessiblecurrentThis table is used to query the ports under a test by board. The indexes of this entry are hwFrameIndex and hwSlotIndex.
1.3.6.1.4.1.2011.6.21.1.1.1.11.1.1ColumnhwMeltTestingPortListread-onlycurrentList of ports under a MELT test on a board. The result is analyzed as follow: If a bit in the bit string is set to 1, it indicates that the corresponding port …
1.3.6.1.4.1.2011.6.21.1.1.1.11.1.2ColumnhwSearchToneTestingPortListread-onlycurrentList of ports under a searching tone test on a board. The result is analyzed as follow: If a bit in the bit string is set to 1, it indicates that the correspon…
1.3.6.1.4.1.2011.6.21.1.1.1.12TablehwWettingCurrentOprTablenot-accessiblecurrentThis table is used for enabling the wetting current by setting the wetting current's working voltage, maximum voltage and slope. The index of this table is ifi…
1.3.6.1.4.1.2011.6.21.1.1.1.12.1RowhwWettingCurrentOprEntrynot-accessiblecurrentThis table is used for enabling the wetting current by setting the wetting current's working voltage, maximum voltage and slope. The index of this entry is ifi…
1.3.6.1.4.1.2011.6.21.1.1.1.12.1.1ColumnhwWettingCurrentOprStatusread-writecurrentWetting Current operation type. Options: 1. enabled(1) -enable a wetting current port 2. disabled(2) -disable a wetting current port 3. invalid(-1) -invalid va…
1.3.6.1.4.1.2011.6.21.1.1.1.12.1.2ColumnhwWettingCurrentOprWorkingVoltageread-writecurrentIndicates the working voltage of a wetting current port. Options: 1. -1 -Invalid value 2. 1..120 -Valid value range Default: 90 Unit: volt
1.3.6.1.4.1.2011.6.21.1.1.1.12.1.3ColumnhwWettingCurrentOprMaximumVoltageread-writecurrentIndicates the maximum voltage of a wetting current port. Options: 1. -1 -Invalid value 2. 1..120 -Valid value range Default: 30 Unit: volt
1.3.6.1.4.1.2011.6.21.1.1.1.12.1.4ColumnhwWettingCurrentOprSloperead-writecurrentIndicates the slope of a wetting current port. Options: 1. -1 -Invalid value 2. 200..20000 -Valid value range Default: 200 Unit: volt per second
1.3.6.1.4.1.2011.6.21.1.1.1.13TablehwLoopLineTestMeltChipStateTablenot-accessiblecurrentThis table is used for manually starting a MELT chip status check on an xDSL board, and obtaining the status of the MELT chip. The indexes of this table are hw…
1.3.6.1.4.1.2011.6.21.1.1.1.13.1RowhwLoopLineTestMeltChipStateEntrynot-accessiblecurrentThis table is used for manually starting a MELT chip status check on an xDSL board, and obtaining the status of the MELT chip. The indexes of this table are hw…
1.3.6.1.4.1.2011.6.21.1.1.1.13.1.1ColumnhwBoardMeltChipStateCheckConfigread-writecurrentEnables the melt chip status check of the board. Options: 1. enabled(1) -Enables the melt chip status check 2. invalid(-1) -Invalid value enabled(1) option is …
1.3.6.1.4.1.2011.6.21.1.1.1.13.1.2ColumnhwBoardMeltChipStateCheckResultaccessible-for-notifycurrentMelt chip status check result. Options: 1. success(1) -Melt chip status check success 2. fail(2) -Melt chip status check fail
1.3.6.1.4.1.2011.6.21.1.1.1.13.1.3ColumnhwPortMeltChipStateListread-onlycurrentLists the status of the MELT chip for xDSL port. The result is analyzed as follow: If a bit in the bit string is set to 1, the MELT chip of a port is faulty. F…
1.3.6.1.4.1.2011.6.21.1.1.1.13.1.4ColumnhwBoardMeltChipStateCheckDCVolUpperLimitread-writecurrentIndicates the upper limit of dc-voltage for melt chip status check. Options: 1. -60..60 -Valid value range 2. 2147483647 -Invalid value Default: 1 Unit: volt
1.3.6.1.4.1.2011.6.21.1.1.1.13.1.5ColumnhwBoardMeltChipStateCheckDCVolLowerLimitread-writecurrentIndicates the lower limit of dc-voltage for melt chip status check. Options: 1. -60..60 -Valid value range 2. 2147483647 -Invalid value Default: -1 Unit: volt
1.3.6.1.4.1.2011.6.21.1.1.1.14NodehwMeltChipStateCheck
1.3.6.1.4.1.2011.6.21.1.1.1.14.1ScalarhwMeltChipStateCheckConfigread-writecurrentEnables or disables MELT chip status check. Options: 1. enabled(1) -Enables MELT chip status check 2. disabled(2) -Disables MELT chip status check Default: dis…
1.3.6.1.4.1.2011.6.21.1.1.1.14.2ScalarhwMeltChipStateCheckTimeread-writecurrentIndicates the start time of the MELT chip status check. This value can be converted into the hexadecimal number 0x00hhmmss (hh representing hour, mm representi…
1.3.6.1.4.1.2011.6.21.1.1.1.14.3ScalarhwMeltChipStateCheckDCVolUpperLimitread-writecurrentIndicates the upper limit of dc-voltage for melt chip status check. Options: 1. -60..60 -Valid value range Default: 1 Unit: volt
1.3.6.1.4.1.2011.6.21.1.1.1.14.4ScalarhwMeltChipStateCheckDCVolLowerLimitread-writecurrentIndicates the lower limit of dc-voltage for melt chip status check. Options: 1. -60..60 -Valid value range Default: -1 Unit: volt
1.3.6.1.4.1.2011.6.21.1.2NodehwTestCommonTraps
1.3.6.1.4.1.2011.6.21.1.2.1NodehwTestCommonTrapVbOids
1.3.6.1.4.1.2011.6.21.1.2.1.2NodehwTestCommonVbOidsReason
1.3.6.1.4.1.2011.6.21.1.2.1.2.1ScalarhwTestClearedReasonaccessible-for-notifycurrentDefinition of the test-canceling reasons. Options: 1. testBoardFail(1) -the test-canceling reason is testBoardFail 2. testedBoardFail(2) -the test-canceling re…
1.3.6.1.4.1.2011.6.21.1.2.1.2.2ScalarhwTestRingSrcAlarmReasonaccessible-for-notifycurrentDefinition of the ringing source alarms. Options: 1. testRingSrcFail(1) -the ringing source alarm is testRingSrcFail 2. testRingSrcRestore(2) -the ringing sour…
1.3.6.1.4.1.2011.6.21.1.2.1.3ScalarhwTestCommonRequestIDaccessible-for-notifycurrentNMS request ID.
1.3.6.1.4.1.2011.6.21.1.2.1.4ScalarhwTestMeltChipIDaccessible-for-notifycurrentMelt chip ID.
1.3.6.1.4.1.2011.6.21.1.2.2NodehwTestCommonAlarmTraps
1.3.6.1.4.1.2011.6.21.1.2.2.0NodehwTestCommonAlarmTrapsOIDs
1.3.6.1.4.1.2011.6.21.1.2.2.0.1NotificationhwTestRingSrcFailTrapcurrentThe btss ring source failed trap: 1: hwTestBoardIfIndex; 2: hwTestRingSrcAlarmReason (1: the ring source of BTSS doesn't work) Troubleshooting suggestions: (1)…
1.3.6.1.4.1.2011.6.21.1.2.2.0.2NotificationhwTestRingSrcRestoreTrapcurrentTest ringing source restore trap: 1: hwTestBoardIfIndex; 2: hwTestRingSrcAlarmReason (1: the ring source of BTSS is normal) The advice: none. This trap will se…
1.3.6.1.4.1.2011.6.21.1.2.2.0.3NotificationhwTestAutoClearedTrapcurrentTrap of test automatically cancelled: 1: hwTestBoardIfIndex; 2: hwTestBoardStatusTestedBoardIfIndex; 3: hwTestClearedReason. This trap will send when the test …
1.3.6.1.4.1.2011.6.21.1.2.2.0.4NotificationhwTestMeltChipFaultAlarmTrapcurrentMELT chip fault trap: 1: hwFrameIndex; 2: hwSlotIndex; 3: hwTestMeltChipID; 4: hwPortMeltChipStateList. When detecting a MELT chip fault, the system generates …
1.3.6.1.4.1.2011.6.21.1.2.2.0.5NotificationhwTestMeltChipRecoveryAlarmTrapcurrentMELT chip fault clear trap: 1: hwFrameIndex; 2: hwSlotIndex; 3: hwTestMeltChipID; 4: hwPortMeltChipStateList. When detecting that a MELT chip fault is cleared,…
1.3.6.1.4.1.2011.6.21.1.2.3NodehwTestCommonGeneralTraps
1.3.6.1.4.1.2011.6.21.1.2.3.0NodehwTestCommonGeneralTrapsOIDs
1.3.6.1.4.1.2011.6.21.1.2.3.0.1NotificationhwLoopLineTestTrapcurrentThis trap will be sent when a loop-line test finished successfully. The trap shows the result of the loop-line test. 1. hwLoopLineTestRequestID, 2. hwLoopLineT…
1.3.6.1.4.1.2011.6.21.1.2.3.0.2NotificationhwMeterTestTrapcurrentMeter test result trap: 1: hwMeterTestStatus. This trap will send when meter test result return.
1.3.6.1.4.1.2011.6.21.1.2.3.0.3NotificationhwTestBoardDiagnoseTestTrapcurrentTest board self-test result trap: 1: hwTestBoardDiagnoseTestResult; 2: hwTestBoardDiagnoseTestRAM; 3: hwTestBoardDiagnoseTestVoltage; 4: hwTestBoardDiagnoseTes…
1.3.6.1.4.1.2011.6.21.1.2.3.0.4NotificationhwTestBoardStatusQueryTrapcurrentTest board status query result trap: 1: hwTestBoardStatusQueryResult; 2: hwTestBoardStatusQueryVersion; 3: hwTestBoardStatusQueryTestItem; 4: hwTestBoardStatus…
1.3.6.1.4.1.2011.6.21.1.2.3.0.5NotificationhwTestOntPotsTestResultTrapcurrentThis trap indicates that a POTS port line test finished successfully, and shows the result of the line test. This trap will send when a POTS port line test fin…
1.3.6.1.4.1.2011.6.21.1.2.3.0.6NotificationhwTestCommonMeltTestResultTrapcurrentThis trap indicates that MELT test finished successfully, and show the result of the melt test This trap will send when the MELT test finished successfully.
1.3.6.1.4.1.2011.6.21.1.2.3.0.7NotificationhwTestCommonMeltTestFaileTrapcurrentThis trap indicates that MELT test fails. This trap will send when the MELT test failed.
1.3.6.1.4.1.2011.6.21.1.2.3.0.8NotificationhwTestMeltChipStateCheckResultTrapcurrentThis trap indicates the MELT chip status check result. This trap will send when the MELT chip status check finished.