TN-IEEE8021-CFM-MIB
148 objects
This document is the SNMP MIB module to manage and provision dot1ag Connectivity Fault Management module functionality for the Nokia 7x50 products. This includes extensions to the IEEE8021-CFM MIB. This SNMP MIB module (Specification) embodies Nokia's proprietary intellectual property. Nokia retains all title and ownership in the Specification, including any revisions. Nokia grants all interested parties a non-exclusive license to use and distribute an unmodified copy of this Specification in connection with management of Nokia products, and without fee, provided this copyright notice and license appear on all copies. This Specification is supplied 'as is', and Nokia makes no warranty, either express or implied, as to the use, operation, condition, or performance of the Specification.
Imported Objects
| OID | Name | Access | Status | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.7483.5.1.3.52 | IdentitytnIEEE8021CfmMIBModule | This document is the SNMP MIB module to manage and provision dot1ag Connectivity Fault Management module functionality for the Nokia 7x50 products. This includ… | ||
| 1.3.6.1.4.1.7483.6.1.2.52 | NodetnDot1agMIBObjs | |||
| 1.3.6.1.4.1.7483.6.1.2.52.1 | NodetnDot1agCfmStack | |||
| 1.3.6.1.4.1.7483.6.1.2.52.1.2 | TabletnDot1agCfmStackTable | not-accessible | current | There is one CFM Stack table per bridge. It permits the retrieval of information about the Maintenance Points configured on any given interface. |
| 1.3.6.1.4.1.7483.6.1.2.52.1.2.1 | RowtnDot1agCfmStackEntry | not-accessible | current | The Stack table entry |
| 1.3.6.1.4.1.7483.6.1.2.52.1.2.1.1 | ColumntnDot1agCfmStackifIndex | not-accessible | current | This object represents the Bridge Port or aggregated port on which MEPs or MHFs might be configured. Upon a restart of the system, the system SHALL, if necessa… |
| 1.3.6.1.4.1.7483.6.1.2.52.1.2.1.2 | ColumntnDot1agCfmStackVlanIdOrNone | not-accessible | current | VLAN ID to which the MP is attached, or 0, if none. |
| 1.3.6.1.4.1.7483.6.1.2.52.1.2.1.3 | ColumntnDot1agCfmStackMdLevel | not-accessible | current | MD Level of the Maintenance Point. |
| 1.3.6.1.4.1.7483.6.1.2.52.1.2.1.4 | ColumntnDot1agCfmStackDirection | not-accessible | current | Direction in which the MP faces on the Bridge Port |
| 1.3.6.1.4.1.7483.6.1.2.52.1.2.1.5 | ColumntnDot1agCfmStackMdIndex | read-only | current | The index of the Maintenance Domain in the dot1agCfmMdTable to which the MP is associated, or 0, if none. |
| 1.3.6.1.4.1.7483.6.1.2.52.1.2.1.6 | ColumntnDot1agCfmStackMaIndex | read-only | current | The index of the MA in the dot1agCfmMaNetTable and dot1agCfmMaCompTable to which the MP is associated, or 0, if none. |
| 1.3.6.1.4.1.7483.6.1.2.52.1.2.1.7 | ColumntnDot1agCfmStackMepId | read-only | current | If an MEP is configured, the MEPID, else 0 |
| 1.3.6.1.4.1.7483.6.1.2.52.1.2.1.8 | ColumntnDot1agCfmStackMacAddress | read-only | current | MAC address of the MP. |
| 1.3.6.1.4.1.7483.6.1.2.52.1.2.1.9 | ColumntnDot1agCfmStackMPType | read-only | current | The value of tnDot1agCfmStackMPType indicates the entity that the MP is configured on: sap(1) MP is configured on a SAP ethTun(2) MP is configured on an ethern… |
| 1.3.6.1.4.1.7483.6.1.2.52.2 | NodetnDot1agCfmGlobalObjs | |||
| 1.3.6.1.4.1.7483.6.1.2.52.2.1 | TabletnDot1agCfmMcLagConfigTable | not-accessible | current | A row in the tnDot1agCfmMcLagConfigTable indicates whether a Mc Lag is in Active Standby or not and what the Hold Time will be. |
| 1.3.6.1.4.1.7483.6.1.2.52.2.1.1 | RowtnDot1agCfmMcLagConfigEntry | not-accessible | current | The Cfm entry for MC LAG |
| 1.3.6.1.4.1.7483.6.1.2.52.2.1.1.1 | ColumntnDot1agCfmMcLagConfigStdbyInactive | read-write | current | The value of tnDot1agCfmMcLagConfigStdbyInactive specifies whether or not ETH-CFM MEPs configured on Multi-Chassis LAG ports are aware of MC-LAG port active/st… |
| 1.3.6.1.4.1.7483.6.1.2.52.2.1.1.2 | ColumntnDot1agCfmMcLagConfigPropHoldTime | read-write | current | The value of tnDot1agCfmMcLagConfigPropHoldTime specifies the duration, in seconds, of a timer that is activated when an MC-LAG port or protocol changes state.… |
| 1.3.6.1.4.1.7483.6.1.2.52.2.3 | NodetnDot1agCfmStatisticsGroup | |||
| 1.3.6.1.4.1.7483.6.1.2.52.2.3.1 | TabletnDot1agCfmComponentLimitTable | not-accessible | current | The tnDot1agCfmComponentLimitTable stores the current resource counts as well as their resource limits for Ethernet Connectivity Fault Management (ETH-CFM) com… |
| 1.3.6.1.4.1.7483.6.1.2.52.2.3.1.1 | RowtnDot1agCfmComponentLimitEntry | not-accessible | current | The tnDot1agCfmComponentLimitEntry consists of the resource limits for a particular component of ETH-CFM. Rows are managed by the system and can not be created… |
| 1.3.6.1.4.1.7483.6.1.2.52.2.3.1.1.1 | ColumntnDot1agCfmCompMajorIndex | not-accessible | current | The value of tnDot1agCfmCompMajorIndex specifies the major identifier of the ETH-CFM component. |
| 1.3.6.1.4.1.7483.6.1.2.52.2.3.1.1.2 | ColumntnDot1agCfmCompMinorIndex | not-accessible | current | The value of tnDot1agCfmCompMinorIndex specifies the minor identifier of the ETH-CFM component. |
| 1.3.6.1.4.1.7483.6.1.2.52.2.3.1.1.3 | ColumntnDot1agCfmCompName | read-only | current | The value of tnDot1agCfmCompName indicates the name of the ETH-CFM component. |
| 1.3.6.1.4.1.7483.6.1.2.52.2.3.1.1.4 | ColumntnDot1agCfmCompResourceUsage | read-only | current | The value of tnDot1agCfmCompResourceUsage indicates the current resource usage for the ETH-CFM component. |
| 1.3.6.1.4.1.7483.6.1.2.52.2.3.1.1.5 | ColumntnDot1agCfmCompResourceLimit | read-only | current | The value of tnDot1agCfmCompResourceLimit indicates the maximum resource usage limit for the ETH-CFM component for the SROS series system. |
| 1.3.6.1.4.1.7483.6.1.2.52.2.101 | ScalartnDot1agCfmGlobalScalar1 | read-only | current | A dummy scalar that satisfies a SNMP get request quickly when there is no 11QPE24 card provisioned. Otherwise, it has to traverse the remaining 11QPE24 MIB to … |
| 1.3.6.1.4.1.7483.6.1.2.52.2.102 | ScalartnDot1agCfmGlobalScalar2 | read-only | current | . |
| 1.3.6.1.4.1.7483.6.1.2.52.6 | NodetnDot1agCfmMa | |||
| 1.3.6.1.4.1.7483.6.1.2.52.6.1 | TabletnDot1agCfmMaNetTable | not-accessible | current | The tnDot1agCfmMaNetTable AUGMENTS the standard MIB table, dot1agCfmMaNetTable. This table is used to enhance Maintenance Association functionality for Etherne… |
| 1.3.6.1.4.1.7483.6.1.2.52.6.1.1 | RowtnDot1agCfmMaNetEntry | not-accessible | current | The tnDot1agCfmMaNetEntry consists of the configuration objects used to enhance the Maintenance Association functionality. |
| 1.3.6.1.4.1.7483.6.1.2.52.6.1.1.1 | ColumntnDot1agCfmMaNetTotalMEPCount | read-only | current | The value of tnDot1agCfmMaNetTotalMEPCount indicates the number of unique MEPs configured (both local and remote) that are associated with this MA. When the nu… |
| 1.3.6.1.4.1.7483.6.1.2.52.6.3 | TabletnDot1agCfmMaMepListTable | not-accessible | current | The tnDot1agCfmMaMepListTable extends the functionality of the dot1agCfmMaMepListTable. |
| 1.3.6.1.4.1.7483.6.1.2.52.6.3.1 | RowtnDot1agCfmMaMepListEntry | not-accessible | current | The tnDot1agCfmMaMepListEntry augments the standard MIB entry for the purpose of extending functionality for Dot1ag CFM MEP Lists. Rows are created and destroy… |
| 1.3.6.1.4.1.7483.6.1.2.52.6.3.1.1 | ColumntnDot1agCfmMaMepListMacAddress | read-create | current | The value of tnDot1agCfmMaMepListMacAddress specifies the target unicast MAC address used for transmitting CFM packets to the remote MEPs for the specified MEP… |
| 1.3.6.1.4.1.7483.6.1.2.52.6.3.1.2 | ColumntnDot1agCfmMaMepListSapSubType | read-create | current | The value of tnDot1agCfmMaMepListSapSubType specifies the SAP sub type of the remote MEP for the specified MEPID. This is used to ensure that LLF shutdown is b… |
| 1.3.6.1.4.1.7483.6.1.2.52.7 | NodetnDot1agCfmMep | |||
| 1.3.6.1.4.1.7483.6.1.2.52.7.1 | TabletnDot1agCfmMepTable | not-accessible | current | This table augments the Maintenance Association End Point (MEP) table of the IEEE8021-CFM-MIB. |
| 1.3.6.1.4.1.7483.6.1.2.52.7.1.1 | RowtnDot1agCfmMepEntry | not-accessible | current | A conceptual row in the tnDot1agCfmMepTable. This row exists only if the association dot1agCfmMepEntry is active. |
| 1.3.6.1.4.1.7483.6.1.2.52.7.1.1.1 | ColumntnDot1agCfmMepSdpId | read-create | current | The value of tnDot1agCfmMepSdpId specifies, along with the tnDot1agCfmMepVcId, the SDP-Binding within a bridge port, to which the MEP is attached. This object … |
| 1.3.6.1.4.1.7483.6.1.2.52.7.1.1.2 | ColumntnDot1agCfmMepVcId | read-create | current | The value of tnDot1agCfmMepVcId specifies, along with tnDot1agCfmMepSdpId, the SDP Binding for the bridge. tnDot1agCfmMepVcId is applicable to SDP-Bindings onl… |
| 1.3.6.1.4.1.7483.6.1.2.52.7.1.1.3 | ColumntnDot1agCfmMepMacAddress | read-create | current | The value of tnDot1agCfmMepMacAddress specifies the mac-address that is assigned to dot1agCfmMepMacAddress. |
| 1.3.6.1.4.1.7483.6.1.2.52.7.1.1.4 | ColumntnDot1agCfmMepAisEnable | read-create | current | The value of tnDot1agCfmMepAisEnable specifies whether AIS frames are generated from the Maintenance Entity Group (MEG). |
| 1.3.6.1.4.1.7483.6.1.2.52.7.1.1.5 | ColumntnDot1agCfmMepAisMegLevel | read-create | current | The value of tnDot1agCfmMepAisMegLevel specifies the levels that should be notified to suppress alarms resulting from defect conditions detected by the MEP. |
| 1.3.6.1.4.1.7483.6.1.2.52.7.1.1.6 | ColumntnDot1agCfmMepAisPriority | read-create | current | The value of tnDot1agCfmMepAisPriority specifies at what priority the AIS frames should be transmitted. |
| 1.3.6.1.4.1.7483.6.1.2.52.7.1.1.7 | ColumntnDot1agCfmMepAisInterval | read-create | current | The value of tnDot1agCfmMepAisInterval specifies at what intervals to transmit AIS frames. |
| 1.3.6.1.4.1.7483.6.1.2.52.7.1.1.8 | ColumntnDot1agCfmMepEthRxAisInterval | read-only | current | The value of tnDot1agCfmMepEthRxAisInterval indicates the AIS Interval received in the last AIS Frame. |
| 1.3.6.1.4.1.7483.6.1.2.52.7.1.1.9 | ColumntnDot1agCfmMepEthRxAis | read-only | current | The value of tnDot1agCfmMepEthRxAis indicates the MEP is receiving AIS test frames from one or more of its sub-layer MEPs. |
| 1.3.6.1.4.1.7483.6.1.2.52.7.1.1.10 | ColumntnDot1agCfmMepEthAisTxCount | read-only | current | The value of tnDot1agCfmMepEthAisTxCount indicates number of AIS frames transmitted on the MEP. |
| 1.3.6.1.4.1.7483.6.1.2.52.7.1.1.11 | ColumntnDot1agCfmMepEthTestEnable | read-create | current | The value of tnDot1agCfmMepEthTestEnable specifies whether ethernet test frames are to be generated on transmission or processed on reception. If this object i… |
| 1.3.6.1.4.1.7483.6.1.2.52.7.1.1.12 | ColumntnDot1agCfmMepEthTestPattern | read-create | current | The value of tnDot1agCfmMepEthTestPattern specifies the data-content of the AIS test frames. 'allZerosNoCrc (0)' and 'allZerosCrc (1)' specifies the data conte… |
| 1.3.6.1.4.1.7483.6.1.2.52.7.1.1.13 | ColumntnDot1agCfmMepEthTestMacAddr | read-create | current | The value of tnDot1agCfmMepEthTestMacAddr specifies the MAC address of the target to whom the Eth-test frames are sent. Setting this object will trigger the te… |
| 1.3.6.1.4.1.7483.6.1.2.52.7.1.1.14 | ColumntnDot1agCfmMepEthTestDataLen | read-create | current | The value of tnDot1agCfmMepEthTestDataLen specifies the length of the data sent in an Eth-test frame. The contents of the data is specified by the tnDot1agCfmM… |
| 1.3.6.1.4.1.7483.6.1.2.52.7.1.1.15 | ColumntnDot1agCfmMepEthTestPriority | read-create | current | The value of tnDot1agCfmMepEthTestPriority specifies the priority used in generating Eth-Test frames. |
| 1.3.6.1.4.1.7483.6.1.2.52.7.1.1.16 | ColumntnDot1agCfmMepOWDTMacAddress | read-create | current | The value of tnDot1agCfmMepOWDTMacAddress specifies the MAC address used as a target for the One-Way-Delay Test (OWDT). Setting this object will trigger a One-… |
| 1.3.6.1.4.1.7483.6.1.2.52.7.1.1.17 | ColumntnDot1agCfmMepOWDTPriority | read-create | current | The value of tnDot1agCfmMepOWDTPriority specifies the priority used in the generated test frame for the One-Way-Delay test. |
| 1.3.6.1.4.1.7483.6.1.2.52.7.1.1.18 | ColumntnDot1agCfmMepTWDTMacAddress | read-create | current | The value of tnDot1agCfmMepTWDTMacAddress specifies the MAC address used as a target for the Two-Way-Delay Test (TWDT). Setting this object will trigger a Two-… |
| 1.3.6.1.4.1.7483.6.1.2.52.7.1.1.19 | ColumntnDot1agCfmMepTWDTPriority | read-create | current | The value of tnDot1agCfmMepTWDTPriority specifies the priority used in the generated test frame for the Two-Way-Delay test. |
| 1.3.6.1.4.1.7483.6.1.2.52.7.1.1.20 | ColumntnDot1agCfmMepSvcId | read-create | current | The value of tnDot1agCfmMepSvcId specifies the service that the virtual MEP is being created in. tnDot1agCfmMepSvcId is applicable to virtual MEPs only, and MU… |
| 1.3.6.1.4.1.7483.6.1.2.52.7.1.1.21 | ColumntnDot1agCfmMepControlMep | read-create | current | The value of tnDot1agCfmMepControlMep specifies whether or not the operational state of the MEP is used by the management entity over which this MEP is configu… |
| 1.3.6.1.4.1.7483.6.1.2.52.7.1.1.22 | ColumntnDot1agCfmMepEthTestThreshold | read-create | current | The value of tnDot1agCfmMepEthTestThreshold specifies when a tnDot1agCfmMepEthTestComplete notification is sent. If tnDot1agCfmMepEthTestThreshold is set to ze… |
| 1.3.6.1.4.1.7483.6.1.2.52.7.1.1.23 | ColumntnDot1agCfmMepOWDTThreshold | read-create | current | The value of tnDot1agCfmMepOWDTThreshold specifies when a tnDot1agCfmMepDMTestComplete notification is sent for a one-way-delay test. If tnDot1agCfmMepOWDTThre… |
| 1.3.6.1.4.1.7483.6.1.2.52.7.1.1.24 | ColumntnDot1agCfmMepMcLagInactive | read-only | current | The value of tmnxDot1agCfmMepMcLagInactive indicates whether or not the MEP is inactive, 'standby (2)', due to the MC-LAG standby state. The value of tmnxDot1a… |
| 1.3.6.1.4.1.7483.6.1.2.52.7.1.1.25 | ColumntnDot1agCfmMepTWDTDataSize | read-create | current | The value of tnDot1agCfmMepTWDTDataSize specifies the data size, in bytes, contained in the padding TLV for the Two-Way delay test. A value of zero (0) specifi… |
| 1.3.6.1.4.1.7483.6.1.2.52.7.1.1.26 | ColumntnDot1agCfmMepTransmitLbmDataTlvSize | read-create | current | The value of tnDot1agCfmMepTransmitLbmDataTlvSize specifies the data size, in bytes, contained in the padding TLV for the LBM test. A value of zero (0) specifi… |
| 1.3.6.1.4.1.7483.6.1.2.52.7.1.1.27 | ColumntnDot1agCfmMepType | read-create | current | The value of tmnxDot1agCfmMepType specifies the endpoint type that this MEP facilitates. default (0) facilityPort (1) facilityInterface (2) sapPrimaryVlan (3) … |
| 1.3.6.1.4.1.7483.6.1.2.52.7.1.1.28 | ColumntnDot1agCfmMepFaultPropagation | read-create | current | The value of tnDot1agCfmMepFaultPropagation specifies what action should be taken by the MEP if a fault is detected in the service containing the MEP. It also … |
| 1.3.6.1.4.1.7483.6.1.2.52.7.1.1.29 | ColumntnDot1agCfmMepOWDTDataSize | read-create | current | The value of tnDot1agCfmMepOWDTDataSize specifies the data size, in bytes, contained in the padding TLV for the one-Way delay test. A value of zero (0) specifi… |
| 1.3.6.1.4.1.7483.6.1.2.52.7.1.1.30 | ColumntnDot1agCfmMepAlmProfName | read-create | current | . |
| 1.3.6.1.4.1.7483.6.1.2.52.7.3 | TabletnDot1agCfmMepDelayRsltTable | not-accessible | current | The tnDot1agCfmMepDelayRsltTable indicates the results of all the One-Way/Two-Way Delay Tests from the originating MAC addresses. This table is not persistent … |
| 1.3.6.1.4.1.7483.6.1.2.52.7.3.1 | RowtnDot1agCfmMepDelayRsltEntry | not-accessible | current | The MEG result table. |
| 1.3.6.1.4.1.7483.6.1.2.52.7.3.1.1 | ColumntnDot1agCfmMepDelaySrcMacAddr | not-accessible | current | The value of tnDot1agCfmMepDelaySrcMacAddr indicates the source MAC address of the issuer of the test. |
| 1.3.6.1.4.1.7483.6.1.2.52.7.3.1.2 | ColumntnDot1agCfmMepDelayTestType | not-accessible | current | The value of tnDot1agCfmMepDelayTestType indicates the type of test this row details. |
| 1.3.6.1.4.1.7483.6.1.2.52.7.3.1.3 | ColumntnDot1agCfmMepDelayTestDelay | read-only | current | The value of tnDot1agCfmMepDelayTestDelay indicates the amount of time, measured in microseconds, from when the test-frame was transmitted to the time it was r… |
| 1.3.6.1.4.1.7483.6.1.2.52.7.3.1.4 | ColumntnDot1agCfmMepDelayVariation | read-only | current | The value of tnDot1agCfmMepDelayVariation indicates the amount of time delay variation, measured in microseconds, from the two most recent time delay measureme… |
| 1.3.6.1.4.1.7483.6.1.2.52.7.3.1.5 | ColumntnDot1agCfmMepDelayNearEndTestDelay | read-only | current | Near end test delay for oneWayTest. |
| 1.3.6.1.4.1.7483.6.1.2.52.7.3.1.6 | ColumntnDot1agCfmMepDelayNearEndVariation | read-only | current | Near end test delay variation for oneWayTest. |
| 1.3.6.1.4.1.7483.6.1.2.52.7.3.1.7 | ColumntnDot1agCfmMepDelayFarEndTestDelay | read-only | current | Far end test delay for oneWayTest |
| 1.3.6.1.4.1.7483.6.1.2.52.7.3.1.8 | ColumntnDot1agCfmMepDelayFarEndVariation | read-only | current | Far end test delay variation for oneWayTest. |
| 1.3.6.1.4.1.7483.6.1.2.52.7.4 | TabletnDot1agCfmMepCsfTable | not-accessible | current | This table augments the Maintenance Association End Point (MEP) table of the IEEE8021-CFM-MIB. |
| 1.3.6.1.4.1.7483.6.1.2.52.7.4.1 | RowtnDot1agCfmMepCsfEntry | not-accessible | current | A conceptual row in the tnDot1agCfmMepCsfTable. This row exists only if the association dot1agCfmMepEntry is active. |
| 1.3.6.1.4.1.7483.6.1.2.52.7.4.1.1 | ColumntnDot1agCfmMepCsfInterval | read-create | current | Interval between CSF transmissions to be used in the MEP. |
| 1.3.6.1.4.1.7483.6.1.2.52.7.4.1.2 | ColumntnDot1agCfmMepCsfDirection | read-write | current | CSF transmissions direction in the MEP |
| 1.3.6.1.4.1.7483.6.1.2.52.7.4.1.3 | ColumntnDot1agCfmMepCsfPriority | read-create | current | The priority value for CSFs transmitted by the MEP. Default Value is the highest priority value allowed to pass through the bridge port for any of this MEPs VI… |
| 1.3.6.1.4.1.7483.6.1.2.52.7.5 | TabletnDot1agCfmMepSlmTWTestTable | not-accessible | current | tnDot1agCfmMepSlmTWTestTable consists of the MEP configuration for issuing individual Synthetic Loss Measurement tests. |
| 1.3.6.1.4.1.7483.6.1.2.52.7.5.1 | RowtnDot1agCfmMepSlmTWTestEntry | not-accessible | current | tnDot1agCfmMepSlmTWTestEntry contains the configuration for generating Synthetic Loss Measurement (SLM) Tests for a particular MEP. A row exists for each row i… |
| 1.3.6.1.4.1.7483.6.1.2.52.7.5.1.1 | ColumntnDot1agCfmMepSlmTWTestStatus | read-create | current | The value of tnDot1agCfmMepSlmTWTestStatus specifies the operational state of the two-way Synthetic Loss Measurement (SLM) test. To issue a two-way SLM test th… |
| 1.3.6.1.4.1.7483.6.1.2.52.7.5.1.2 | ColumntnDot1agCfmMepSlmTWTestId | read-only | current | The value of tnDot1agCfmMepSlmTWTestId indicates the test identifier used to initiate the two-way Synthetic Loss Measurement (SLM) test. |
| 1.3.6.1.4.1.7483.6.1.2.52.7.5.1.3 | ColumntnDot1agCfmMepSlmTWMacAddress | read-create | current | The value of tnDot1agCfmMepSlmTWMacAddress specifies the MAC address used as a target for the two-way Synthetic Loss Measurement (SLM) test. This object MUST b… |
| 1.3.6.1.4.1.7483.6.1.2.52.7.5.1.4 | ColumntnDot1agCfmMepSlmTWPriority | read-create | current | The value of tnDot1agCfmMepSlmTWPriority specifies the priority used in the generated test frame for the two-way Synthetic Loss Measurement (SLM) test. |
| 1.3.6.1.4.1.7483.6.1.2.52.7.5.1.5 | ColumntnDot1agCfmMepSlmTWInterval | read-create | current | The value of tnDot1agCfmMepSlmTWInterval specifies the delay, in seconds, between Synthetic Loss Measurement (SLM) messages for the two-way SLM test. Following… |
| 1.3.6.1.4.1.7483.6.1.2.52.7.5.1.6 | ColumntnDot1agCfmMepSlmTWTimeout | read-create | current | The value of tnDot1agCfmMepSlmTWTimeout specifies the time-out value, in seconds, to wait for a Synthetic Loss Measurement (SLM) message to reply for the two-w… |
| 1.3.6.1.4.1.7483.6.1.2.52.7.5.1.7 | ColumntnDot1agCfmMepSlmTWDataSize | read-create | current | The value of tnDot1agCfmMepSlmTWDataSize specifies the data size, in bytes, contained in the padding TLV for the two-way Synthetic Loss Measurement (SLM) test.… |
| 1.3.6.1.4.1.7483.6.1.2.52.7.5.1.8 | ColumntnDot1agCfmMepSlmTWSendCount | read-create | current | The value of tnDot1agCfmMepSlmTWSendCount specifies the number of Synthetic Loss Measurement (SLM) packets to send during the two-way SLM test. |
| 1.3.6.1.4.1.7483.6.1.2.52.7.5.1.9 | ColumntnDot1agCfmMepSlmTWIntervalRedef | read-create | current | The value of tnDot1agCfmMepSlmTWIntervalRedef specifies the interval of SLM frames transmitted. The permitted values are 100ms(0),1s (1),10s(2),1m(3),10(4). |
| 1.3.6.1.4.1.7483.6.1.2.52.7.5.1.10 | ColumntnDot1agCfmMepSlmTWIntrvlUnits | read-create | current | The value of tnDot1agCfmMepSlmTWIntrvlUnits, in conjuction with tnDot1agCfmMepSlmTWInterval, specifies the interval between Synthetic Loss Measurement (SLM) me… |
| 1.3.6.1.4.1.7483.6.1.2.52.7.6 | TabletnDot1agCfmMepSlmOWTestTable | not-accessible | current | tnDot1agCfmMepSlmOWTestTable consists of the MEP configuration for issuing individual Synthetic Loss Measurement one-way tests. |
| 1.3.6.1.4.1.7483.6.1.2.52.7.6.1 | RowtnDot1agCfmMepSlmOWTestEntry | not-accessible | current | tnDot1agCfmMepSlmOWTestEntry contains the configuration for generating Synthetic Loss Measurement (SLM) Tests for a particular MEP. A row exists for each row i… |
| 1.3.6.1.4.1.7483.6.1.2.52.7.6.1.1 | ColumntnDot1agCfmMepSlmOWTestStatus | read-create | current | The value of tnDot1agCfmMepSlmOWTestStatus specifies the operational state of the one-way Synthetic Loss Measurement (SLM) test. To issue a one-way SLM test th… |
| 1.3.6.1.4.1.7483.6.1.2.52.7.6.1.2 | ColumntnDot1agCfmMepSlmOWTestId | read-only | current | The value of tnDot1agCfmMepSlmOWTestId indicates the test identifier used to initiate the one-way Synthetic Loss Measurement (SLM) test. |
| 1.3.6.1.4.1.7483.6.1.2.52.7.6.1.3 | ColumntnDot1agCfmMepSlmOWMacAddress | read-create | current | The value of tnDot1agCfmMepSlmOWMacAddress specifies the MAC address used as a target for the one-way Synthetic Loss Measurement (SLM) Test. This object MUST b… |
| 1.3.6.1.4.1.7483.6.1.2.52.7.6.1.4 | ColumntnDot1agCfmMepSlmOWPriority | read-create | current | The value of tnDot1agCfmMepSlmOWPriority specifies the priority used in the generated test frame for the one-way Synthetic Loss Measurement (SLM) test. |
| 1.3.6.1.4.1.7483.6.1.2.52.7.6.1.5 | ColumntnDot1agCfmMepSlmOWInterval | read-create | current | The value of tnDot1agCfmMepSlmOWInterval specifies the delay, in seconds, between Synthetic Loss Measurement (SLM) messages for the one-way SLM test. |
| 1.3.6.1.4.1.7483.6.1.2.52.7.6.1.6 | ColumntnDot1agCfmMepSlmOWDataSize | read-create | current | The value of tnDot1agCfmMepSlmOWDataSize specifies the data size, in bytes, contained in the padding TLV for the one-way Synthetic Loss Measurement (SLM) test.… |
| 1.3.6.1.4.1.7483.6.1.2.52.7.6.1.7 | ColumntnDot1agCfmMepSlmOWSendCount | read-create | current | The value of tnDot1agCfmMepSlmOWSendCount specifies the number of Synthetic Loss Measurement (SLM) packets to send consecutively during the one-way SLM test. |
| 1.3.6.1.4.1.7483.6.1.2.52.7.7 | TabletnDot1agCfmMepSlmTestRsltTable | not-accessible | current | tnDot1agCfmMepSlmTestRsltTable consists of the results of manually triggered Synthetic Loss Measurement tests. |
| 1.3.6.1.4.1.7483.6.1.2.52.7.7.1 | RowtnDot1agCfmMepSlmTestRsltEntry | not-accessible | current | tnDot1agCfmMepSlmTestRsltEntry contains the results of a manually triggered Synthetic Loss Measurement (SLM) test for a particular MEP. Rows are auto-generated… |
| 1.3.6.1.4.1.7483.6.1.2.52.7.7.1.1 | ColumntnDot1agCfmMepSlmTestType | not-accessible | current | The value of tnDot1agCfmMepSlmTestType specifies whether the row for this Synthetic Loss Measurement (SLM) test refers to a two-way SLM test. |
| 1.3.6.1.4.1.7483.6.1.2.52.7.7.1.2 | ColumntnDot1agCfmMepSlmRemoteMacAddr | not-accessible | current | The value of tnDot1agCfmMepSlmRemoteMacAddr specifies the source MAC address of the remote node involved in the test. |
| 1.3.6.1.4.1.7483.6.1.2.52.7.7.1.3 | ColumntnDot1agCfmMepSlmTestId | read-only | current | The value of tnDot1agCfmMepSlmTestId indicates the test identifier that was used to initiate the Synthetic Loss Measurement (SLM) test. |
| 1.3.6.1.4.1.7483.6.1.2.52.7.7.1.4 | ColumntnDot1agCfmMepSlmRemoteMepId | read-only | current | The value of tnDot1agCfmMepSlmRemoteMepId indicates the MEP Identifier of the remote node involved in the test. |
| 1.3.6.1.4.1.7483.6.1.2.52.7.7.1.5 | ColumntnDot1agCfmMepSlmLastTxSeqF | read-only | current | The value of tnDot1agCfmMepSlmLastTxSeqF indicates the last received sequence number on the local node, transmitted by the remote node. |
| 1.3.6.1.4.1.7483.6.1.2.52.7.7.1.6 | ColumntnDot1agCfmMepSlmPacketIn | read-only | current | The value of tnDot1agCfmMepSlmPacketIn indicates the number of packets received during the execution of the test. |
| 1.3.6.1.4.1.7483.6.1.2.52.7.7.1.7 | ColumntnDot1agCfmMepSlmPacketLossIn | read-only | current | The value of tnDot1agCfmMepSlmPacketLossIn indicates the number of packets transmitted from the remote node but not received on the local node during the execu… |
| 1.3.6.1.4.1.7483.6.1.2.52.7.7.1.8 | ColumntnDot1agCfmMepSlmPacketLossOut | read-only | current | The value of tnDot1agCfmMepSlmPacketLossOut indicates the number of packets transmitted from the local node but not received on the remote node during the exec… |
| 1.3.6.1.4.1.7483.6.1.2.52.7.7.1.9 | ColumntnDot1agCfmMepSlmPacketUnack | read-only | current | The value of tnDot1agCfmMepSlmPacketUnack indicates the number of unacknowledged lost packets during the execution of the test. |
| 1.3.6.1.4.1.7483.6.1.2.52.7.8 | TabletnDot1agCfmMepOndemandLmTestTable | not-accessible | current | tnDot1agCfmMepOndemandLmTestTable consists of the MEP configuration for issuing individual on-demand Regular Loss Measurement tests. |
| 1.3.6.1.4.1.7483.6.1.2.52.7.8.1 | RowtnDot1agCfmMepOndemandLmTestEntry | not-accessible | current | tnDot1agCfmMepOndemandLmTestEntry contains the configuration for generating regular Loss Measurement (LM) Tests for a particular MEP. A row exists for each row… |
| 1.3.6.1.4.1.7483.6.1.2.52.7.8.1.1 | ColumntnDot1agCfmMepOndemandLmTestStatus | read-create | current | The value of tnDot1agCfmMepOndemandLmTestStatus specifies the operational state of the on-demand regular Loss Measurement (LM) test. To issue a on-demand regul… |
| 1.3.6.1.4.1.7483.6.1.2.52.7.8.1.2 | ColumntnDot1agCfmMepOndemandLmDestMacAddress | read-create | current | The value of tnDot1agCfmMepOndemandLmMacAddress specifies the MAC address used as a target for the on-demand regular Loss Measurement (LM) test. This object MU… |
| 1.3.6.1.4.1.7483.6.1.2.52.7.8.1.3 | ColumntnDot1agCfmMepOndemandLmPriority | read-create | current | The value of tnDot1agCfmMepOndemandLmPriority specifies the priority used in the generated test frame for the on-demand regular Loss Measurement (LM) test. |
| 1.3.6.1.4.1.7483.6.1.2.52.7.8.1.4 | ColumntnDot1agCfmMepOndemandLmInterval | read-create | current | The value of tnDot1agCfmMepOndemandLmInterval specifies the delay, in seconds, between on-demand regular Loss Measurement (LM) messages for the on-demand regul… |
| 1.3.6.1.4.1.7483.6.1.2.52.7.8.1.5 | ColumntnDot1agCfmMepOndemandLmSendCount | read-create | current | The value of tnDot1agCfmMepOndemandLmSendCount specifies the number of LMM packets to send during the on-demand regular LM test. |
| 1.3.6.1.4.1.7483.6.1.2.52.7.8.1.6 | ColumntnDot1agCfmMepOndemandLmTimeout | read-create | current | The value of tnDot1agCfmMepOndemandLmTimeout specifies the time-out value, in milliseconds, to wait for a response message for the two-way LM test. Upon expira… |
| 1.3.6.1.4.1.7483.6.1.2.52.7.9 | TabletnDot1agCfmMepOndemandLmTestRsltTable | not-accessible | current | tnDot1agCfmMepOndemandLmTestRsltTable consists of the results of manually triggered on-demand regular Loss Measurement tests. |
| 1.3.6.1.4.1.7483.6.1.2.52.7.9.1 | RowtnDot1agCfmMepOndemandLmTestRsltEntry | not-accessible | current | tnDot1agCfmMepOndemandLmTestRsltEntry contains the results of a manually triggered on-demand regular Loss Measurement (LM) test. Rows are auto-generated by the… |
| 1.3.6.1.4.1.7483.6.1.2.52.7.9.1.1 | ColumntnDot1agCfmMepOndemandLmTnTF | read-only | current | The value of tnDot1agCfmMepOndemandLmTnTF indicates the total number of near-end transmitted service frames from the remote node during the execution of the te… |
| 1.3.6.1.4.1.7483.6.1.2.52.7.9.1.2 | ColumntnDot1agCfmMepOndemandLmTnLF | read-only | current | The value of tnDot1agCfmMepOndemandLmTnLF indicates the total number of near-end lost service frames on the local node during the execution of the test. |
| 1.3.6.1.4.1.7483.6.1.2.52.7.9.1.3 | ColumntnDot1agCfmMepOndemandLmTfTF | read-only | current | The value of tnDot1agCfmMepOndemandLmTfTF indicates the total number of far-end transmitted service frames from the local node during the execution of the test. |
| 1.3.6.1.4.1.7483.6.1.2.52.7.9.1.4 | ColumntnDot1agCfmMepOndemandLmTfLF | read-only | current | The value of tnDot1agCfmMepOndemandLmTfLF indicates the total number of far-end lost service frames on the remote node during the execution of the test. |
| 1.3.6.1.4.1.7483.6.1.2.52.7.9.1.5 | ColumntnDot1agCfmMepOndemandLmUnack | read-only | current | The value of tnDot1agCfmMepOndemandLmUnack indicates the number of unacknowledged lost LM packets during the execution of the test. |
| 1.3.6.1.4.1.7483.6.1.2.52.7.9.1.6 | ColumntnDot1agCfmMepOndemandLmRemoteMacAddr | read-only | current | The MAC address of the remote node involved in the test. |
| 1.3.6.1.4.1.7483.6.1.2.52.7.10 | TabletnDot1agCfmMepOWDelayRsltExtTable | not-accessible | current | The tnDot1agCfmMepOWDelayRsltExtTable indicates the near-end One-way Delay result. This table is not persistent over reboots of the chassis. |
| 1.3.6.1.4.1.7483.6.1.2.52.7.10.1 | RowtnDot1agCfmMepOWDelayRsltExtEntry | not-accessible | current | The near-end one-way delay test result table. |
| 1.3.6.1.4.1.7483.6.1.2.52.7.10.1.1 | ColumntnDot1agCfmMepOWDelayRsltExtTnFD | read-only | current | The value of tnDot1agCfmMepOWDelayRsltExtTnFD indicates one-way near-end frame delay from remote MEP to local MEP. It is the amount of time, measured in micros… |
| 1.3.6.1.4.1.7483.6.1.2.52.7.10.1.2 | ColumntnDot1agCfmMepOWDelayRsltExtTnFDV | read-only | current | The value of tnDot1agCfmMepDelayVariation indicates the amount of near-end one-way time delay variation, measured in microseconds, from the two most recent nea… |
| 1.3.6.1.4.1.7483.6.1.2.52.7.101 | ScalartnDot1agCfmMepScalar1 | read-only | current | A dummy scalar that satisfies a SNMP get request quickly when there is no 11QPE24 card provisioned. Otherwise, it has to traverse the remaining 11QPE24 MIB to … |
| 1.3.6.1.4.1.7483.6.1.2.52.7.102 | ScalartnDot1agCfmMepScalar2 | read-only | current | . |
| 1.3.6.1.4.1.7483.6.1.3.52 | NodetnDot1agNotificationsPrefix | |||
| 1.3.6.1.4.1.7483.6.1.3.52.0 | NodetnDot1agNotifications | |||
| 1.3.6.1.4.1.7483.6.1.3.52.0.1 | NotificationtnDot1agCfmMepLbmTestComplete | current | The tnDot1agCfmMepLbmTestComplete notification indicates that a loopback test has been issued and results are ready. | |
| 1.3.6.1.4.1.7483.6.1.3.52.0.2 | NotificationtnDot1agCfmMepLtmTestComplete | current | The tnDot1agCfmMepLtmTestComplete notification indicates that a linktrace test has been issued and results are ready. The dot1agCfmMepTransmitLtmSeqNumber indi… | |
| 1.3.6.1.4.1.7483.6.1.3.52.0.4 | NotificationtnDot1agCfmMepDMTestComplete | current | The tnDot1agCfmMepDMTestComplete notification indicates that a One-Way-Delay-Test (OWDT) frame, or a Two-Way-Delay-Test (TWDT) response was received. For an OW… | |
| 1.3.6.1.4.1.7483.6.1.3.52.0.5 | NotificationtnDot1agCfmMepAisStateChanged | current | The tnDot1agCfmMepAisStateChanged notification is generated when a MEP enters or exits an AIS state. | |
| 1.3.6.1.4.1.7483.6.1.3.52.0.7 | NotificationtnDot1agCfmMepSLMTestComplete | current | The tnDot1agCfmMepSLMTestComplete notification is generated when a two-way Synthetic Loss Measurement (SLM) test is completed. | |
| 1.3.6.1.4.1.7483.6.1.3.52.0.8 | NotificationtnDot1agCfmMepOndemandLmTestComplete | current | The tnDot1agCfmMepOndemandLmTestComplete notification is generated when a on-demand regular Loss Measurement (LM) test is completed. |
Type Definitions
| Name | Syntax | Status | Description |
|---|---|---|---|
| NokiaPmonUnitType | INTEGER { microseconds(1), hundred-nano-seconds(2), nano-seconds(3) } | current | Statistics unit type for proactive and on-demand OAM PM. |